FLUKE-77-4 Fluke Electronics, FLUKE-77-4 Datasheet - Page 12

MULTIMETER INDUSTRIAL 1000V CAT

FLUKE-77-4

Manufacturer Part Number
FLUKE-77-4
Description
MULTIMETER INDUSTRIAL 1000V CAT
Manufacturer
Fluke Electronics
Series
77 IVr
Type
Digital (DMM)r
Datasheet

Specifications of FLUKE-77-4

Includes
Battery, Test Leads
Style
Handheld
Display Digits
3.75
Display Type
LCD, Bar Graph
Display Count
6000
Function
Voltage, Current, Resistance, Capacitance, Frequency
Functions, Extra
Continuity, Diode Test
Features
Backlight, Hold, Min/Max/Ave, Sleep
Ranging
Auto/Manual
Response
Average
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
2727486
614-1085
77-4
FLUKE-77-4
Model 77 Series IV
Users Manual
Measuring AC or DC Current
Turn power OFF, break circuit, insert Meter in series, turn power
on.
8
To avoid personal injury or damage to the Meter:
Never attempt to make an in-circuit current measure-
ment when the open-circuit potential to earth ground
is 1000 V.
Check the Meter's fuses before testing. (See “Testing
the Fuses”.)
Use the proper terminals, switch position, and range
for your measurement.
Never place the probes in parallel with a circuit or
component when the leads are plugged into the
current terminals.
XWWarning
+
+
HOLD
MIN MAX
RANGE
CAT
CAT
A
mA
AIK08F.EPS
DC
Measuring Frequency
The Meter measures the frequency of a signal. The trigger level is
0 V ac for all ranges.
To avoid electrical shock, disregard the bar graph for
frequencies >1 kHz. If the frequency of the measured
signal is >1 kHz, the bar graph is unspecified.
To exit frequency, press yellow button or turn the rotary
switch.
In frequency, the bar graph shows the ac voltage accurately
up to 1 kHz.
Select progressively lower ranges using manual ranging for a
stable reading.
AC Voltage Frequency
V
+
XWWarning
HOLD
MIN MAX
RANGE
Hz
EOM09F.EPS