FLUKE-114 Fluke Electronics, FLUKE-114 Datasheet

MULTMETR ELEC DMM 6000CNT 600V

FLUKE-114

Manufacturer Part Number
FLUKE-114
Description
MULTMETR ELEC DMM 6000CNT 600V
Manufacturer
Fluke Electronics
Series
11xr
Type
Digital (DMM), Testerr
Datasheets

Specifications of FLUKE-114

Includes
Battery, Test Leads
Style
Handheld
Display Digits
3.75
Display Type
LCD, Bar Graph
Display Count
6000
Function
Voltage, Resistance
Functions, Extra
Continuity
Features
Backlight, Hold, Min/Max/Ave, Sleep
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Vendor undefined / RoHS compliant by exemption
Other names
2538783
614-1009
®
114, 115, and 117
True-rms Multimeters
Users Manual
PN 2572573
July 2006, Rev. 1, 2/07
© 2006, 2007 Fluke Corporation, All rights reserved. Printed in China
All product names are trademarks of their respective companies.

FLUKE-114 Summary of contents

Page 1

... PN 2572573 July 2006, Rev. 1, 2/07 © 2006, 2007 Fluke Corporation, All rights reserved. Printed in China All product names are trademarks of their respective companies. 114, 115, and 117 True-rms Multimeters Users Manual ® ...

Page 2

... LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable bat- teries, or damage from accident, neglect, misuse, alteration, contamination, or abnor- mal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’ ...

Page 3

... Introduction The Fluke Model 114, Model 115, and Model 117 are battery-powered, true-rms multimeters (hereafter "the Meter") with a 6000-count display and a bar graph. This manual applies to all three models. All figures show the Model 117. These meters meet CAT III IEC 61010 standards ...

Page 4

Users Manual Safety Information A "XWWarning" statement identifies hazardous conditions and actions that could cause bodily harm or death. A "WCaution" statement identifies conditions and actions that could damage the Meter or the equipment under test. ...

Page 5

... B AC (Alternating Current (Direct Current) X Hazardous voltage N Battery (Low battery when shown on the display.) Do not dispose of this product as unsorted ~ municipal waste. Contact Fluke or a qualified recycler for disposal. True-rms Multimeters Symbols I Fuse T Double Insulated W Important Information; Refer to manual J Earth ground ...

Page 6

Users Manual Display No. Symbol A w The Meter is in the VoltAlert™ non-contact voltage detect mode The Meter function is set to Continuity The ...

Page 7

... W The input is too large for the selected range LEAd W Test lead alert. Briefly displayed whenever the Meter’s function switch is rotated to or from any A position. True-rms Multimeters Display 114, 115, & 117 114, 115, & 117 117 114, 115 & 117 114, 115, & ...

Page 8

Users Manual Terminals No. A Input terminal for measuring ac and dc current Common (return) terminal for all measurements. Input terminal for measuring voltage, continuity, resistance, capacitance, C frequency and testing diodes. ...

Page 9

... Note: All ac functions and Auto-V LoZ are true-rms. AC voltage is ac-coupled. Auto-V LoZ and AC amps are dc-coupled. Measurement Function and turns off at 250 . displayed. True-rms Multimeters Rotary Switch Positions Model 114 & 117 114, 115 & 117 115 & 117 114, 115 & 117 114, 115 & ...

Page 10

Users Manual Battery Saver ("Sleep Mode") The Meter automatically enters "Sleep mode" and blanks the display if there is no function change, range change, or button press for 20 minutes. Pressing any button or turning the ...

Page 11

... When connecting the test leads to the circuit or device, connect the common (COM) test lead before connecting the live lead; when removing the test leads, remove the live lead before removing the common test lead. True-rms Multimeters Power-Up Options Power-Up Options Turns on all display segments. ...

Page 12

Users Manual Measuring Resistance XWWarning To avoid electric shock, injury, or damage to the Meter, disconnect circuit power and discharge all high- voltage capacitors before testing resistance, continuity, diodes, or capacitance. 10 Testing for Continuity edy04f.eps ...

Page 13

... Volts DC readings due to ghost voltages. Measuring AC and DC Millivolts Millivolts AC edy03f.eps With the function switch in the l position, the Meter measures ac plus dc millivolts. Press g to switch the Meter to dc millivolts. True-rms Multimeters Making Basic Measurements Millivolts DC DC edy18f.eps 11 ...

Page 14

Users Manual Measuring Current (115 & 117) XWWarning To avoid personal injury or damage to the Meter: Never attempt to make an in-circuit current measurement when the open- circuit potential to earth is ...

Page 15

... Current Probe to measure currents that exceed the rating of the Meter. Make sure the Meter has the correct function selected DC, for your current probe. Refer to a Fluke catalog or contact your local Fluke representative for compatible current clamps. Making Basic Measurements Measuring Capacitance (115 & ...

Page 16

Users Manual Measuring Frequency (115 & 117 only) XWWarning To avoid electrical shock, disregard the bar graph for frequencies >1 kHz. If the frequency of the measured signal is >1 kHz, the bar graph and Z ...

Page 17

... Capacitance mode. In this mode, capacitance measurements will have a lower accuracy and lower dynamic range. This setting is not saved when the Meter is turned off or goes into sleep mode. True-rms Multimeters Making Basic Measurements Testing Diodes (115 & 117) Good Diode Good Diode ...

Page 18

Users Manual Using the Bargraph The bar graph is like the needle on an analog meter. It has an overload indicator (>) to the right and a polarity indicator (+)to the left. Because the bar graph ...

Page 19

... Lift the door straight up to separate it from the case. The battery fits inside the battery door, which is then inserted into the case, bottom edge first, until it is fully seated. Do not attempt to install the battery directly into the case. 5. Install and tighten battery door screw. True-rms Multimeters Maintenance edy11f.eps 17 ...

Page 20

... Separate the case bottom from the case top. 5. Remove the fuse from its holder and replace it with 1000 V, FAST fuse having a minimum interrupt rating of 17,000 A. Use only Fluke PN 803293 re-assemble the Meter, first attach the case bottom to the case top, then install the two screws. Finally, insert the Meter into its holster ...

Page 21

... Maximum voltage between any terminal and earth ground ...................................... 600 V Surge Protection ..................................................... 6 kV peak per IEC 61010-1 600V CAT III, W Fuse for A input (115 & 117 only): .................... 11 A, 1000 V FAST 17 kA Fuse (Fluke PN 803293) Display ..................................................................... Digital: 6,000 counts, updates 4/sec Temperature............................................................. Operating: -10 ° °C Temperature Coefficient ......................................... 0.1 x (specified accuracy)/ C (< ...

Page 22

Users Manual Certifications ............................................................UL, IP Rating (dust and water protection) Function Range DC millivolts 600.0 mV 6.000 V DC Volts 60.00 V 600.0 V [1] 600.0 V Auto-V LoZ True-rms [1] True- AC millivolts 600.0 mV ...

Page 23

... Reading] + [Counts]) Beeper on < off > 250 1 detects opens or shorts of 500 s or longer. 0.1 0.001 k 0.01 k 0.1 k 0.001 M 0.01 M 0.001 0. 100 F - 1000 F: 1 500 F True-rms Multimeters General Specifications Accuracy ; > 1000 10 typical Model 114, 115, ...

Page 24

Users Manual Function Range 6.000 A AC Amps True- [3] 10.00 A [1] rms 20 A for 30 seconds max., ( 500 Hz) 10 minutes rest min. 6.000 A [3] 10. Amps ...

Page 25

... Open Circuit Test Voltage Ohms <2 Diode Test <2 Table 2. Input Characteristics Common Mode Rejection Ratio (1 k Unbalanced) > dc >100 > dc Full Scale Voltage To 6.0 M <0 2.000 V dc True-rms Multimeters General Specifications Normal Mode Rejection > Short Circuit Current 40 M <350 A <0 <1 ...

Page 26

Users Manual 24 ...