FLUKE-115 Fluke Electronics, FLUKE-115 Datasheet - Page 2

MULTMETR DMM 6000CNT 600V

FLUKE-115

Manufacturer Part Number
FLUKE-115
Description
MULTMETR DMM 6000CNT 600V
Manufacturer
Fluke Electronics
Series
11xr
Type
Digital (DMM)r
Datasheets

Specifications of FLUKE-115

Includes
Battery, Test Leads
Style
Handheld
Display Digits
3.75
Display Type
LCD, Bar Graph
Display Count
6000
Function
Voltage, Current, Resistance, Capacitance, Frequency
Functions, Extra
Continuity, Diode Test
Features
Backlight, Hold, Min/Max/Ave, Sleep
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Vendor undefined / RoHS compliant by exemption
Other names
2538790
614-1010
Notes:
1
2
2 Fluke Corporation 115 Multimeter
Accuracy specifications
All ac voltage ranges are specified from 1 % to 100 % of range. Because inputs below 1 % of range are not specified,
it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected
from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full
scale. AC volts is ac coupled and ac mV is dc coupled.
Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
Measurement
DC millivolts
DC volts
Auto volts
AC millivolts
true-rms
AC volts
Continuity
Ohms
Diode test
Capacitance
Lo-Z capacitance
AC amps true-rms
(45 Hz to 500 Hz)
DC amps
Hz (V or A input)
1
true-rms
1
2
Range
600.0 mV
6.000 V
60.00 V
600.0 V
600.0 V
600.0 mV
6.000 V
60.00 V
600.0 V
600 Ω
600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
40.00 MΩ
2.000 V
1000 nF
10.00 µF
100.0 µF
9999 µF
100 µF to 1000 µF
> 1000 µF
1 nF to 500 µF
6.000 A
10.00 A
20 A overload for 30 seconds max.
6.000 A
10.00 A
20 A overload for 30 seconds max.
99.99 Hz
999.9 Hz
9.999 kHz
50.00 kHz
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
0.1 V
0.1 mV
0.001 V
0.01 V
0.1 V
1 Ω
0.1Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.001 V
1 nF
0.01 µF
0.1 µF
1 µF
0.001 A
0.01 A
0.001 A
0.01 A
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
1.9 % + 2
5 % + 20
Accuracy ± ([% of reading] + [counts])
0.5 % + 2
0.5 % + 2
2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
1.0 % + 3 (45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Beeper on < 20 Ω off > 250 Ω; detects
opens or shorts of 500 µs or longer.
0.9 % + 2
0.9 % + 1
1.5 % + 2
0.9 % + 2
1.9 % + 2
10 % + 2 typical
1.5 % + 3
1.0 % + 3
0.1 % + 2
Fluke. Keeping your world
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa (31 40) 2 675 200 or
Fax (31 40) 2 675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2006 Fluke Corporation. All rights reserved.
Specifications subject to change without notice.
Printed in U.S.A. 10/2006 2634043 D-EN-N Rev B
Ordering
information
Fluke-115
Included
TL75 Test leads, holster, User’s
manual and 9 V battery (installed).
up and running.
Multimeter