MLX90333KDC-BCH Melexis Inc, MLX90333KDC-BCH Datasheet - Page 26

IC 3D-JOYSTICK POS SENSOR 8-SOIC

MLX90333KDC-BCH

Manufacturer Part Number
MLX90333KDC-BCH
Description
IC 3D-JOYSTICK POS SENSOR 8-SOIC
Manufacturer
Melexis Inc
Datasheet

Specifications of MLX90333KDC-BCH

Featured Product
MLX90333 Series Contactless Sensors
Sensor Type
3D
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MLX90333KDC
MLX90333KDC

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MLX90333KDC-BCH-000-SP
Manufacturer:
Melexis
Quantity:
1 200
Part Number:
MLX90333KDC-BCH-000-TU
Manufacturer:
FREESCALE
Quantity:
101
Part Number:
MLX90333KDC-BCH-100-RE
Manufacturer:
Melexis
Quantity:
1 200
Part Number:
MLX90333KDC-BCH-100-SP
Manufacturer:
Melexis
Quantity:
1 400
Part Number:
MLX90333KDC-BCH-100-TU
Manufacturer:
Melexis
Quantity:
1 200
14.4. Identification
Identification number: 48 bits freely useable by Customer for traceability purpose.
14.5. Sensor Front-End
14.5.1. HIGHSPEED Parameter
The HIGHSPEED parameter defines the main frequency for the DSP.
For better noise performance, the Slow Mode must be enabled.
14.5.2. GAINMIN and GAINMAX Parameters
The MLX90333 features an automatic gain control (AGC) of the analog chain. The AGC loop is based on
and it targets an amplitude of 90% of the ADC input span.
In MLX90333BCT, this default target is changed to 64% but can be set to 90% by enabling the parameter
AGCRADIUSTARGET.
The current gain can be read out with the programming unit PTC-04 and gives a rough indication of the
applied magnetic flux density (Amplitude).
GAINMIN & GAINMAX define the boundaries within the gain setting is allowed to vary. Outside this range,
the outputs are set in diagnostic low.
14.5.3. FIELDTHRES_LOW and FIELDTHRES_HIGH Parameters
The strength of the applied field is constantly calculated in a background process. The value of this field
can be read out with the PTC-04 and gives a rough indication of the applied magnetic flux density
(Amplitude).
FIELDTHRES_LOW & FIELDTHRES_HIGH define the boundaries within the actual field strength
(Radius) is allowed to vary. Outside this range, the outputs are set in diagnostic low.
3901090333
Rev. 003
HIGHSPEED = 0 selects the Slow mode with a 7 MHz master clock.
HIGHSPEED = 1 selects the Fast mode with a 20 MHz master clock.
FIELDTHRES_HIGH
FIELDTHRES_LOW
CUSTUMERID1
CUSTUMERID2
CUSTUMERID3
HIGHSPEED
MELEXSID1
MELEXSID2
MELEXSID3
Parameter
Parameter
GAINMAX
GAINMIN
Max(|V
X
|, |V
Y
|, |V
Z
Page 26 of 46
|) = |Amplitude| = Radius
0 = Slow mode
1 = Fast mode
0 … 65535
0 … 65535
0 … 65535
0 … 65535
0 … 65535
0 … 65535
0 … 100
0 … 100
0 … 41
0 … 41
Value
Value
Tria ⊗ is ™ Position Sensor
Unit
Unit
%
%
MLX90333
Data Sheet
Feb. 11