MTCBA-G2 Multi-Tech Systems, MTCBA-G2 Datasheet - Page 22

no-image

MTCBA-G2

Manufacturer Part Number
MTCBA-G2
Description
MODEM GPRS CELLULAR SERIAL
Manufacturer
Multi-Tech Systems
Series
MultiModem® Cellr
Datasheets

Specifications of MTCBA-G2

Function
Transceiver, GPRS, Modem
Modulation Or Protocol
GPRS
Frequency
850MHz, 900MHz, 1.8GHz, 1.9GHz
Applications
General Purpose
Interface
Serial
Data Rate - Maximum
85.6kbps
Voltage - Supply
9 V ~ 32 V
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
881-1153

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MTCBA-G2
Manufacturer:
Multi-Tech Systems
Quantity:
135
Chapter 3 – Using your Wireless Modem
Generic Dial-Up Method - Non-Windows
22
Serial Baud Rate
Your MultiModem Cell is defaulted to a serial baud rate of 115200 from the factory. To enjoy faster baud rates, you can
manually set the modem to a higher speed (230400, 460800, or 921600) using the AT+IPR=<baudspeed>. However, you
must make sure the host serial port is capable of the new speed. If the new speed is set and the host hardware is not capable
of the higher speed, you will need to find a host that is capable.
1.
2.
If CDMA, dial onto the network using AT#777
If GPRS/EDGE:
a.
b.
To set up an Access Point Name (APN) enter:
AT+CGDCONT=1, “IP”,”<APNSERVER>”
Where <APNSERVER> is the APN server supplied by your carrier
dial onto the network using AT*99***1#
Multi-Tech Systems, Inc. MultiModem Cell User Guide