SI824XCLASSD-KIT Silicon Laboratories Inc, SI824XCLASSD-KIT Datasheet - Page 8

BOARD EVAL FOR SI824X

SI824XCLASSD-KIT

Manufacturer Part Number
SI824XCLASSD-KIT
Description
BOARD EVAL FOR SI824X
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of SI824XCLASSD-KIT

New! Us2012 Catalog Page
Class-D Audio Driver_Precision Clock ICs
Board Type
Fully Populated
Amplifier Type
Class D
Output Type
2-Channel (Stereo)
Max Output Power X Channels @ Load
120W x 2 @ 8 Ohm
Utilized Ic / Part
Si824x
Description/function
Audio Amplifiers
Operating Supply Voltage
12 V
Output Power
30 W to 1000 W
Product
Audio Development Tools
Supply Current
500 mA
For Use With/related Products
Si824x
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Supply
-
Operating Temperature
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
336-2002
Si824x
Table 2. Absolute Maximum Ratings
Table 3. Regulatory Information*
8
Parameter
Storage Temperature
Ambient Temperature under Bias
Input-side Supply Voltage
Driver-side Supply Voltage
Voltage on any Pin with respect to Ground
Output Drive Current per Channel
Lead Solder Temperature (10 sec)
Latchup Immunity
Maximum Isolation (Input to Output)
Maximum Isolation (Output to Output)
Notes:
CSA
The Si824x is certified under CSA Component Acceptance Notice 5A. For more details, see File 232873.
61010-1: Up to 300 V
60950-1: Up to 300 V
VDE
The Si824x is certified according to IEC 60747-5-2. For more details, see File 5006301-4880-0001.
60747-5-2: Up to 560 V
UL
The Si824x is certified under UL1577 component recognition program. For more details, see File E257455.
Rated up to 2500 V
*Note: Regulatory Certifications apply to 2.5 kV
1. Permanent device damage may occur if the absolute maximum ratings are exceeded. Functional operation should be
2. VDE certifies storage temperature from –40 to 150 °C.
3. Latchup immunity specification is for slew rate applied across GNDI and GNDA or GNDB.
restricted to the conditions as specified in the operational sections of this data sheet. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
For more information, see "6.Ordering Guide" on page 25.
3
RMS
2
RMS
RMS
peak
isolation voltage for basic protection.
reinforced insulation working voltage; up to 600 V
reinforced insulation working voltage; up to 600 V
for basic insulation working voltage.
1
RMS
rated devices, which are production tested to 3.0 kV
VDDA, VDDB
Symbol
Rev. 0.2
VDDI
T
VIN
STG
T
I
O
A
–0.6
–0.6
–0.5
Min
–65
–40
RMS
RMS
Typ
basic insulation working voltage.
basic insulation working voltage.
VDD + 0.5
+150
+125
2500
1500
Max
260
100
6.0
30
10
RMS
for 1 sec.
Units
V
V
V/ns
mA
°C
°C
°C
RMS
RMS
V
V
V

Related parts for SI824XCLASSD-KIT