Z8FS040BSB20EG Zilog, Z8FS040BSB20EG Datasheet - Page 26

IC MCU 4KB FLASH IRDA 8SOIC

Z8FS040BSB20EG

Manufacturer Part Number
Z8FS040BSB20EG
Description
IC MCU 4KB FLASH IRDA 8SOIC
Manufacturer
Zilog
Series
ZMOTION™r

Specifications of Z8FS040BSB20EG

Applications
Infrared Motion Detection
Core Processor
eZ8
Program Memory Type
FLASH (4 kB)
Controller Series
Z8 Encore! XP®
Interface
IrDA, UART/USART
Number Of I /o
5
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 105°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (0.154", 3.90mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Ram Size
-
Other names
269-2512

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z8FS040BSB20EG
Manufacturer:
SAMSUNG
Quantity:
1 150
Address
PIR Status/Control Register 0 (ePIR_SC0)
Extended Detection Level (Bit 6-7)
Engine Disabled (Bit 5)
PS028506-1110
Control
Field
Bit
Sets the sensitivity level of extended detector
Controlled by application
These 2 bits enhance the motion detection algorithms to detect slower, faster and/or more subtle
motion. The Extended Detection level is selected to provide a balance between additional sensitivity
while maintaining stability (no false detections). In certain applications such as lighting control the
Extended Detection level can be increased once ‘normal’ motion has been detected. Extended
detection is dependent on the lens pattern used. Smaller lens beams tend to provide more subtle
motion detection.
The Extended Detection level effects user control over the range provided in ePIR_SC2. As the
Extended Detection level is increased, the Range setting becomes less effective.
00 = Extended Detection Level 0 – Minimum (least sensitive)
01 = Extended Detection Level 1
10 = Extended Detection Level 2
11 = Extended Detection Level 3 – High (most sensitive)
PIR Engine Disable/Suspend Acknowledged
Controlled by PIR engine
This bit indicates the operational status of and is controlled by the PIR engine. When the engine is
initialized and enabled by loading the PIR Enable Register with the ePIR_ENABLE_PATTERN value,
this bit is cleared to indicate that the Engine is ready. When the Engine is disabled by loading the PIR
Enable Register with the ePIR_DISABLE_PATTERN, it will respond by setting this bit to 1 and perform
no further operations until re-enabled. In order for the Engine to detect that it has been disabled, the
user must allow the Engine ADC interrupt to run at least once after loading the PIR Enable Register with
the ePIR_DISABLE_PATTERN.
0 = Engine is enabled and operational
1 = Engine is disabled and not operational
Extended Detection
7
R/W
6
Disabled
Engine
R
5
PRELIMINARY
Suspend
R/W
MD
4
102H
Direction
Control
Motion
R/W
ZMOTION
3
Direction
Motion
TM
R
Detection and Control Family
2
Product Specification
Detected
Motion
R/W
1
Stable
PIR
R
0
21