ADUM5000ARWZ-RL Analog Devices Inc, ADUM5000ARWZ-RL Datasheet - Page 6

no-image

ADUM5000ARWZ-RL

Manufacturer Part Number
ADUM5000ARWZ-RL
Description
Isolated DC/DC Converter
Manufacturer
Analog Devices Inc
Series
IsoPower®, iCoupler®r
Datasheet

Specifications of ADUM5000ARWZ-RL

Design Resources
USB Cable Isolator Circuit (CN0159)
Inputs - Side 1/side 2
2/0
Number Of Channels
2
Isolation Rating
2500Vrms
Voltage - Supply
2.7 V ~ 5.5 V
Output Type
Logic
Package / Case
16-SOIC (0.300", 7.5mm Width)
Operating Temperature
-40°C ~ 105°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Data Rate
-
Propagation Delay
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM5000ARWZ-RL
Manufacturer:
AD
Quantity:
1 670
Part Number:
ADUM5000ARWZ-RL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADuM5000
IEC 60747-5-2 (VDE 0884, PART 2):2003-01 INSULATION CHARACTERISTICS
This power module is suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured
by protective circuits. The * marking branded on the component designates IEC 60747-5-2 (VDE 0884, Part 2):2003-01 approval.
Table 8.
Description
Installation Classification per DIN VDE 0110
Climatic Classification
Pollution Degree per DIN VDE 0110, Table 1
Maximum Working Insulation Voltage
Input-to-Output Test Voltage
Highest Allowable Overvoltage
Safety-Limiting Values
Insulation Resistance at T
Thermal Derating Curve
RECOMMENDED OPERATING CONDITIONS
Table 9.
Parameter
TEMPERATURE
SUPPLY VOLTAGES
1
2
Operation at 105°C requires reduction of the maximum load current as specified in Table 10.
Each voltage is relative to its respective ground.
Method b1
Method a
Operating Temperature
V
V
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
Case Temperature
Side 1 I
DD1
DD1
After Environmental Tests Subgroup 1
After Input and/or Safety Test
at V
at V
Subgroup 2 and Subgroup 3
DD1
SEL
SEL
Current
= 0 V
= 5 V
1
2
Figure 2. Thermal Derating Curve, Dependence of Safety Limiting Values on Case Temperature, per DIN EN 60747-5-2)
S
Symbol
T
V
V
A
DD1
DD1
600
500
400
300
200
100
Conditions
V
partial discharge < 5 pC
V
V
Transient overvoltage, t
Maximum value allowed in the event of a failure
(see Figure 2)
V
0
IORM
IORM
IORM
IO
0
= 500 V
× 1.875 = V
× 1.6 = V
× 1.2 = V
Min
−40
2.7
4.5
50
AMBIENT TEMPERATURE (°C)
PR
PR
Rev. A | Page 6 of 16
, t
, t
PR
Max
5.5
5.5
+105
m
m
, 100% production test, t
= 60 sec, partial discharge < 5 pC
= 60 sec, partial discharge < 5 pC
100
TR
= 10 sec
Unit
°C
V
V
150
Comments
Each voltage is relative to its respective ground
m
= 1 sec,
200
Symbol
V
V
V
I
R
V
T
S1
S
IORM
PR
PR
TR
S
Characteristic
I to IV
I to III
I to II
40/105/21
2
560
1050
896
672
4000
150
555
>10
9
Unit
V peak
V peak
V peak
V peak
V peak
°C
mA
Ω

Related parts for ADUM5000ARWZ-RL