ADSP-21065LKSZ-264 Analog Devices Inc, ADSP-21065LKSZ-264 Datasheet - Page 22

ADSP-21065L 66MHz

ADSP-21065LKSZ-264

Manufacturer Part Number
ADSP-21065LKSZ-264
Description
ADSP-21065L 66MHz
Manufacturer
Analog Devices Inc
Series
SHARC®r
Type
Fixed/Floating Pointr
Datasheet

Specifications of ADSP-21065LKSZ-264

Interface
Host Interface, Serial Port
Clock Rate
60MHz
Non-volatile Memory
External
On-chip Ram
64kB
Voltage - I/o
3.30V
Voltage - Core
3.30V
Operating Temperature
0°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
208-MQFP, 208-PQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADSP-21065LKSZ-264
Manufacturer:
AKM
Quantity:
12 000
Part Number:
ADSP-21065LKSZ-264
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
ADSP-21065LKSZ-264
Manufacturer:
ADI/PBF
Quantity:
240
Part Number:
ADSP-21065LKSZ-264
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADSP-21065L
Multiprocessor Bus Request and Host Bus Request
Use these specifications for passing of bus mastership between multiprocessing ADSP-21065Ls (BRx) or a host processor (HBR,
HBG).
Parameter
Timing Requirements:
t
t
t
t
t
t
t
Switching Characteristics:
t
t
t
t
t
t
t
t
t
NOTES
1
2
3
4
For first asynchronous access after HBR and CS asserted, ADDR
Only required for recognition in the current cycle.
CPA assertion must meet the setup to CLKIN; deassertion does not need to meet the setup to CLKIN.
(O/D) = open drain, (A/D) = active drive.
HBGRCSV
SHBRI
HHBRI
SHBGI
HHBGI
SBRI
HBRI
DHBGO
HHBGO
DBRO
HBRO
DCPAO
TRCPA
DRDYCS
TRDYHG
ARDYTR
low. This is easily accomplished by driving an upper address signal high when HBG is asserted. See the Host Processor Control of the ADSP-21065L section of the
ADSP-21065L SHARC User’s Manual, Second Edition.
HBG Low to RD/WR/CS Valid
HBR Setup Before CLKIN
HBR Hold Before CLKIN
HBG Setup Before CLKIN
HBG Hold Before CLKIN High
BRx, CPA Setup Before CLKIN
BRx, CPA Hold Before CLKIN High
HBG Delay After CLKIN
HBG Hold After CLKIN
BRx Delay After CLKIN
BRx Hold After CLKIN
CPA Low Delay After CLKIN
CPA Disable After CLKIN
REDY (O/D) or (A/D) Low from CS and HBR Low
REDY (O/D) Disable or REDY (A/D) High from HBG
REDY (A/D) Disable from CS or HBR High
2
2
1
3
23-0
must be a nonMMS value 1/2 t
4
–22–
4
4
CK
before RD or WR goes low or by t
Min
12.0 + 12 DT
6.0 + 8 DT
7.0 + 8 DT
1.0 – 2 DT
1.0 – 2 DT
1.0 – 2 DT
44.0 + 43 DT
Max
20.0 + 36 DT
6.0 + 12 DT
1.0 + 8 DT
1.0 + 8 DT
8.0 – 2 DT
7.0 – 2 DT
11.5 – 2 DT
5.5 – 2 DT
13.0
10.0
HBGRCSV
after HBG goes
REV. C
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns