ADIS16367/PCBZ Analog Devices Inc, ADIS16367/PCBZ Datasheet - Page 16

no-image

ADIS16367/PCBZ

Manufacturer Part Number
ADIS16367/PCBZ
Description
ADIS16367/PCB EVAL. BD. PB Free
Manufacturer
Analog Devices Inc
Series
iMEMS®, iSensor™r
Datasheets

Specifications of ADIS16367/PCBZ

Sensor Type
Accelerometer, Gyroscope, 3 Axis
Sensing Range
±18g, ±300°/sec, ±600°/sec, ±1200°/sec
Sensitivity
3.33mg/LSB, 0.05 ~ 0.2°/sec/LSB
Voltage - Supply
4.75 V ~ 5.25 V
Embedded
No
Utilized Ic / Part
ADIS16367
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Interface
-
Lead Free Status / Rohs Status
Compliant
ADIS16367
Alarm Registers
The alarm function provides monitoring for two independent
conditions. The ALM_CTRL register provides control inputs
for data source, data filtering (prior to comparison), static
comparison, dynamic rate-of-change comparison, and output
indicator configurations. The ALM_MAGx registers establish
the trigger threshold and polarity configurations. Table 30 gives
an example of how to configure a static alarm. The ALM_SMPLx
registers provide the numbers of samples to use in the dynamic
rate-of-change configuration. The period equals the number in
the ALM_SMPLx register multiplied by the sample period time,
which is established by the SMPL_PRD register. See Table 31 for
an example of how to configure the sensor for this type of function.
Table 27. ALM_MAG1, ALM_MAG2 Bit Descriptions
Bits
[15]
[14]
[13:0]
Table 28. ALM_SMPL1, ALM_SMPL2 Bit Descriptions
Bits
[15:8]
[7:0]
Table 29. ALM_CTRL Bit Descriptions
Bits
[15:12]
[11:8]
[7]
[6]
[5]
[4]
[3]
[2]
[1]
[0]
Description (Default = 0x0000)
Comparison polarity (1 = greater than, 0 = less than)
Not used
Data bits that match the format of the trigger
source selection
Description (Default = 0x0000)
Not used
Data bits: number of samples (both 0x00 and 0x01 = 1)
Description (Default = 0x0000)
Alarm 2 source selection
0000 = disable
0001 = power supply output
0010 = x-axis gyroscope output
0011 = y-axis gyroscope output
0100 = z-axis gyroscope output
0101 = x-axis accelerometer output
0110 = y-axis accelerometer output
0111 = z-axis accelerometer output
1000 = x-axis gyroscope temperature output
1001 = y-axis gyroscope temperature output
1010 = z-axis gyroscope temperature output
1011 = auxiliary ADC input
Alarm 1 source selection (same as Alarm 2)
Rate-of-change enable for Alarm 2 (1 = rate of change,
0 = static level)
Rate-of-change enable for Alarm 1 (1 = rate of change,
0 = static level)
Not used
Comparison data filter setting (1 = filtered data,
0 = unfiltered data)
Not used
Alarm output enable (1 = enabled, 0 = disabled)
Alarm output polarity (1 = active high, 0 = active low)
Alarm output line select (1 = DIO2, 0 = DIO1)
Rev. A | Page 16 of 20
Table 30. Alarm Configuration Example 1
DIN
0xAF55,
0xAE17
0xA700,
0xA696
0xA937,
0xA86A
Table 31. Alarm Configuration Example 2
DIN
0xAF76,
0xAEC7
0xB601
0xAA08
0xAC50
0xA700,
0xA696
0xA937,
0xA86A
PRODUCT IDENTIFICATION
Table 32 provides a summary of the registers that identify
the product: PROD_ID, which identifies the product type;
LOT_ID1 and LOT_ID2, the 32-bit lot identification code;
and SERIAL_NUM, which displays the 12-bit serial number.
All four registers are two bytes in length. When using the
SERIAL_NUM value to calculate the serial number, mask
off the upper four bits and convert the remaining 12 bits to a
decimal number.
Table 32. Identification Registers
Register Name
LOT_ID1
LOT_ID2
PROD_ID
SERIAL_NUM
Description
ALM_CTRL = 0x5517
Alarm 1 input = XACCL_OUT
Alarm 2 input = XACCL_OUT
Static level comparison, filtered data
DIO2 output indicator, positive polarity
ALM_MAG1 = 0x8096
Alarm 1 is true if XACCL_OUT > +0.5 g
ALM_MAG2 = 0x376A
Alarm 2 is true if XACCL_OUT < −0.5 g
Description
ALM_CTRL = 0x76C7
Alarm 1 input = YACCL_OUT
Alarm 2 input = ZACCL_OUT
Rate-of-change comparison, unfiltered data
DIO2 output indicator, positive polarity
SMPL_PRD = 0x0001
Sample rate = 819.2 SPS
ALM_SMPL1 = 0x0008
Alarm 1 rate-of-change period = 9.77 ms
ALM_SMPL2 = 0x0050
Alarm 2 rate-of-change period = 97.7 ms
ALM_MAG1 = 0x8096
Alarm 1 is true if YACCL_OUT increases by more than
0.5 g in 9.77 ms.
ALM_MAG2 = 0x376A
Alarm 2 is true if ZACCL_OUT decreases by more
than 0.5 g in 97.7 ms.
Address
0x52
0x54
0x56
0x58
Description
Lot Identification Code 1
Lot Identification Code 2
Product identification = 0x3FEF
(hexadecimal number for 16,367)
Serial number