AD7147PACPZ-1RL Analog Devices Inc, AD7147PACPZ-1RL Datasheet - Page 49

CAPACITANCE TO DIGITAL CONVERTER

AD7147PACPZ-1RL

Manufacturer Part Number
AD7147PACPZ-1RL
Description
CAPACITANCE TO DIGITAL CONVERTER
Manufacturer
Analog Devices Inc
Series
CapTouch™r
Type
Capacitive Sensor Controllerr
Datasheet

Specifications of AD7147PACPZ-1RL

Resolution (bits)
16 b
Data Interface
I²C, Serial
Voltage Supply Source
Single Supply
Voltage - Supply
2.6 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-LFCSP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Sampling Rate (per Second)
-
Lead Free Status / Rohs Status
Compliant
Table 29. STAGE_HIGH_INT_STATUS Register
Address
0x009
1
Registers self-clear to 0 after readback if the limits are not exceeded.
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[15:12]
Data Bit
Default
Value
0
0
0
0
0
0
0
0
0
0
0
0
Type
R
R
R
R
R
R
R
R
R
R
R
R
Name
STAGE0_HIGH_INT_STATUS
STAGE1_HIGH_INT_STATUS
STAGE2_HIGH_INT_STATUS
STAGE3_HIGH_INT_STATUS
STAGE4_HIGH_INT_STATUS
STAGE5_HIGH_INT_STATUS
STAGE6_HIGH_INT_STATUS
STAGE7_HIGH_INT_STATUS
STAGE8_HIGH_INT_STATUS
STAGE9_HIGH_INT_STATUS
STAGE10_HIGH_INT_STATUS
STAGE11_HIGH_INT_STATUS
Unused
1
Rev. B | Page 49 of 72
STAGE0 CDC conversion high limit interrupt result
STAGE1 CDC conversion high limit interrupt result
Stage2 CDC conversion high limit interrupt result
STAGE3 CDC conversion high limit interrupt result
STAGE4 CDC conversion high limit interrupt result
STAGE5 CDC conversion high limit interrupt result
STAGE6 CDC conversion high limit interrupt result
STAGE7 CDC conversion high limit interrupt result
STAGE8 CDC conversion high limit interrupt result
STAGE9 CDC conversion high limit interrupt result
STAGE10 CDC conversion high limit interrupt result
STAGE11 CDC conversion high limit interrupt result
Description
1 = indicates STAGE0_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE1_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE2_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE3_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE4_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE5_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE6_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE7_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE8_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE9_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE10_HIGH_THRESHOLD value was
exceeded
1 = indicates STAGE11_HIGH_THRESHOLD value was
exceeded
Set to 0
AD7147

Related parts for AD7147PACPZ-1RL