1658537-3 TE Connectivity, 1658537-3 Datasheet - Page 3

D SUB CONTACT, SOCKET, 24-20AWG, CRIMP

1658537-3

Manufacturer Part Number
1658537-3
Description
D SUB CONTACT, SOCKET, 24-20AWG, CRIMP
Manufacturer
TE Connectivity
Type
Contactr
Series
AMPLIMITE HDP-20r
Datasheets

Specifications of 1658537-3

Number Of Contacts
1POS
Number Of Terminals
1
Plug / Receptacle
SKT
Contact Plating
Au over Pd Ni
Contact Pitch (mm)
Not Requiredmm
Body Orientation
Straight
Mounting Style
Cable
Number Of Ports
1Port
Number Of Contact Rows
Not Required
Termination Method
Crimp
Housing Material
Not Required
Contact Material
Phosphor Bronze
Product Length (mm)
14.1mm
Product Depth (mm)
2.41mm
Wire Size (awg)
24-20
Contact Termination
Crimp
Rohs Compliant
Yes
Contact Gender
Socket
Product Type
Contact
Product Series
HDP-20 (Crimp Snap)
Termination Method To Wire/cable
Crimp
Wire Insulation Diameter (mm [in])
1.27 – 1.52 [0.050 – 0.060]
Insulation Support
Yes
Grade
Standard
Contact Retention In Housing
Crimp Snap-In
Solder Tail Contact Plating
Tin
Wire Range (mm² [awg])
0.2 - 0.6 [24-20]
Used With
CPC Connectors, AMPLIMITE HDP-20
Contact Type
Socket
Contact Base Material
Phosphor Bronze
Contact Plating, Mating Area, Material
Gold Flash over Palladium Nickel or Gold (30) over Nickel
Contact Size
20
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Packaging Method
Strip
Lead Free Status / RoHS Status
Compliant
For Use With
CPC Connectors, AMPLIMITE HDP-20
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
1658537-3
Manufacturer:
TE
Quantity:
20 000
Part Number:
1658537-3
Manufacturer:
TE
Quantity:
35 000
Tem perature rise vs current.
Vibration, random .
Mechanical shock.
Durability.
Mating force.
Unm ating force.
Contact insertion force.
Rev F
Test Description
30°C m axim um tem perature rise at
specified current.
No discontinuities of 1 m icrosecond
or longer duration.
See Note.
No discontinuities of 1 m icrosecond
or longer duration.
See Note.
See Note.
Size Posn
Size Posn
13.3 N [3 lbf] m axim um per contact. EIA-364-5.
1
2
3
4
5
1
2
3
4
5
15
25
37
50
15
25
37
50
9
9
Figure 1 (continued)
MECHANICAL
Requirem ent
12.5 [2.8]
20.9 [4.7]
34.7 [7.8]
51.6 [11.6] 177.9 [40]
69.4 [15.6] 195.7 [44]
12.5 [2.8]
20.9 [4.7]
34.7 [7.8]
51.6 [11.6] 177.9 [40]
69.4 [15.6] 195.7 [44]
(N [lbf] m axim um )
W ithout
(N [lbf] m axim um )
W ithout
Ground Indents
Ground Indents
133.4 [30]
146.8 [33]
164.6 [37]
133.4 [30]
146.8 [33]
164.6 [37]
W ith
W ith
EIA-364-70, Method 1.
Stabilize at a single current level
until 3 readings at 5 m inute intervals
are within 1°C.
See Figure 4.
EIA-364-28, Test Condition V,
Condition F.
Subject m ated specim ens to 20.71
G's rm s between 50 to 2000 Hz.
Fifteen m inutes in each of 3
m utually perpendicular planes.
See Figure 5.
EIA-364-27, Method A.
Subject m ated specim ens to 50 G's
half-sine shock pulses of 11
m illiseconds duration. Three shocks
in each direction applied along 3
m utually perpendicular planes, 18
total shocks.
See Figure 5.
EIA-364-9.
Mate and unm ate gold flash
specim ens for 100 cycles, and 30
ìin gold specim ens for 500 cycles
at a m axim um rate of 200 cycles
per hour.
EIA-364-13.
Measure force necessary to m ate
specim ens at a m axim um rate of
25.4 m m [1 in] per m inute.
EIA-364-13.
Measure force necessary to unm ate
specim ens at a m axim um rate of
25.4 m m [1 in] per m inute.
Measure force necessary to insert
contact into housing.
Procedure
108-40005
3 of 10