Specifications of 110MT160KPBF

Product
Three Phase Bridge
Peak Reverse Voltage
1600 V
Max Surge Current
1000 A
Forward Voltage Drop
1.4 V
Maximum Reverse Leakage Current
10000 uA
Maximum Operating Temperature
+ 150 C
Length
94 mm
Width
35 mm
Height
30 mm
Mounting Style
Screw
Minimum Operating Temperature
- 40 C
Package / Case
INT-A-PAK
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
110MT160KPBF
Manufacturer:
IR
Quantity:
120
90-110MT.KPbF Series
Vishay High Power Products
www.vishay.com
2
FORWARD CONDUCTION
PARAMETER
Maximum DC output current at case
temperature
Maximum peak, one-cycle
forward, non-repetitive surge current
Maximum I
Maximum I
Low level value of
threshold voltage
High level value of threshold voltage
Low level value of forward
slope resistance
High level value of forward
slope resistance
Maximum forward voltage drop
RMS isolation voltage
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER
Maximum junction operating and
storage temperature range
Maximum thermal resistance,
junction to case
Maximum thermal resistance,
case to heatsink per module
Mounting
torque ± 10 %
Approximate weight
2
2
t for fusing
√t for fusing
to heatsink
to terminal
SYMBOL
SYMBOL
For technical questions, contact: ind-modules@vishay.com
T
V
V
V
R
R
J
I
F(TO)1
F(TO)2
V
I
FSM
, T
ISOL
I
I
2
r
r
thJC
thCS
2
FM
O
f1
f2
√t
t
Stg
(Power Modules), 90/110 A
120° rect. conduction angle
t = 10 ms
t = 8.3 ms
t = 10 ms
t = 8.3 ms
t = 10 ms
t = 8.3 ms
t = 10 ms
t = 8.3 ms
t = 0.1 to 10 ms, no voltage reapplied
(16.7 % x π x I
(I > π x I
(16.7 % x π x I
(I > π x I
I
t
T
f = 50 Hz, t = 1 s
DC operation per module
DC operation per junction
120° rect. conduction angle per module
120° rect. conduction angle per junction
Mounting surface smooth, flat and greased
A mounting compound is recommended and
the torque should be rechecked after a period
of 3 hours to allow for the spread of the
compound. Lubricated threads.
pk
p
J
= 400 µs single junction
Three Phase Bridge
= 25 °C, all terminal shorted
= 150 A, T
F(AV)
F(AV)
), T
), T
J
TEST CONDITIONS
TEST CONDITIONS
F(AV)
F(AV)
= 25 °C
No voltage
reapplied
100 % V
reapplied
No voltage
reapplied
100 % V
reapplied
J
J
maximum
maximum
< I < π x I
< I < π x I
RRM
RRM
F(AV)
F(AV)
Initial
T
J
), T
), T
= T
J
J
J
maximum
maximum
maximum
90 (120)
90MT.K
90MT.K
90 (61)
30 000
3000
2700
2100
1900
0.21
1.26
0.25
1.47
0.89
1.05
5.11
770
810
650
680
1.6
- 40 to 150
4 to 6
3 to 4
4000
Document Number: 94352
4.64
0.03
176
110 (150)
110MT.K
110MT.K
90 (57)
45 000
1000
4500
4100
3200
2900
0.81
0.99
4.37
Revision: 29-Apr-08
950
800
840
0.18
1.07
0.21
1.25
1.4
UNITS
UNITS
A
°C/W
A
Nm
°C
2
°C
A
A
V
V
2
g
√s
s

Related parts for 110MT160KPBF