V600-D23P66N Omron, V600-D23P66N Datasheet - Page 8

RFID Modules & Development Tools 256 BYTE RFID TAG

V600-D23P66N

Manufacturer Part Number
V600-D23P66N
Description
RFID Modules & Development Tools 256 BYTE RFID TAG
Manufacturer
Omron
Datasheet

Specifications of V600-D23P66N

Frequency Range
530kHz
Memory Size
256Byte
Width
34mm
Tag Memory
EEPROM
Read/write Cycles
100000
Diameter
8mm
Height
3.5mm
Tag Technology
Passive
Depth
34mm
For Use With
V600 RFID
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
■ ID Controllers
■ Monitor Unit
V600-P01 (for use with V600-CA@A Controllers)
The Monitor Unit is a monitoring device that can be mounted to an ID
Controller. It can be used to test communications between the R/W
Head and Data Carrier when the RFID System is started up, check
the data in Data Carriers, and read error information or statistical
error information.
The specifications conform to those of the ID Controller, except the
operating temperature range is 0°C to 40°C.
Item
Host interface
Possible number of R/W
Heads
Power supply voltage
Acceptable power supply
voltage
Power consumption
Insulation resistance
Dielectric strength
Noise immunity
Vibration
resistance
Shock resistance
Ambient temperature
Ambient humidity
Operating conditions
Storage temperature
Memory back-up
Diagnostic functions
Ground
Degree of protection
Weight
Destruction
Malfunction
Series
Model
RS-232C
2
100 to 240 VAC, 50/60 Hz
85 to 264 VAC
35 VA max.
50 MΩ min. (at 500 VDC) between power terminals and case, between I/O terminals and case, or between the power
supply terminals and I/O terminals
1,500 VAC, 50/60 Hz for 1 min between the points listed above;
Leakage current: 10 mA max.
1,500-V (p-p) pulses of 100-ns to 1-µs pulse width with a 1-ns rise time
10 to 150 Hz, 0.3-mm double amplitude for 32 min each in X, Y, and Z directions
10 to 150 Hz, 0.2-mm double amplitude for 32 min each in X, Y, and Z directions
Destruction: 200 m/s
−10 to 55°C
35% to 85% (with no condensation)
No corrosive gases
−25 to 65°C
A capacitor backs up the most recent error data and statistical error data for
up to 20 days (at 25°C) after a power interruption.
Checks for CPU errors, memory errors, power interruptions, and transmission errors
Ground to 100 Ω or less.
IEC 60529: IP30 (panel mounted)
Approx. 890 g
V600-CA1A-V2
RS-422A
(Maximum of 16
Units can be
connected)
Approx. 930 g
V600-CA2A-V2
2
3 times each in X, Y, and Z directions (18 times total)
V600 Series (Electromagnetic RFID System)
Parallel
PNP output
Approx. 960 g
Electromagnetic Coupling RFID System
V600-CA8A-V2
Parallel
NPN output
V600-CA9A-V2
RS-232C
1
24 VDC
20.4 to 26.4 VDC 20.4 to 26.4 VDC
7.2 W max.
1,000 VAC, 50/60 Hz for 1 min
between the points listed above;
Leakage current: 10 mA max.
Memory backup is not available. Error
details, however, can be read from the
personal computer when the power is
turned ON.
Approx 360 g
V600-CD1D-V3
V600
24 VDC, 5 VDC
4.5 to 5.5 VDC
24 VDC:
7.2 W max.
5 VDC:
1.5 W max.
0 to 50°C
−15 to 70°C
Approx. 180 g
V600-CM1D
9

Related parts for V600-D23P66N