MAX2659EVKIT+ Maxim Integrated Products, MAX2659EVKIT+ Datasheet - Page 2

no-image

MAX2659EVKIT+

Manufacturer Part Number
MAX2659EVKIT+
Description
RF Modules & Development Tools MAX2659 EVAL KIT MAX2659 EVAL KIT
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX2659EVKIT+

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
• An RF signal generator capable of delivering RF
• An RF spectrum analyzer that covers the MAX2659
• One DC power supply capable of up to 50mA at 1.6V
• Power meter capable of measuring up to 0dBm
• One ammeter to measure the supply current (option-
• A noise figure meter (optional)
• A network analyzer for measuring gain and return
The MAX2659 EV kit is fully assembled and tested.
Follow the steps below for a step-by-step guide to
operating the EV kit and testing the device functions.
Connect pin 1 to pin 2 of JP1 to enable the device.
Caution: Do not turn on the DC power or RF signal
generators until all connections are completed.
1) Connect a DC supply set to +2.85V to the V
MAX2659 Evaluation Kit
Figure 1. MAX2659 EV Kit Schematic
2
power as high as 0dBm at the 1575.42MHz operating
frequency, such as the HPE4433B or equivalent
operating frequency range, as well as a few harmon-
ics, such as the FSEB20 or equivalent
to 3.3V
al)
loss (optional)
GND terminals (through an ammeter, if desired) on
the EV kit. Do not turn on the supply.
_______________________________________________________________________________________
Connections and Setup
Required Equipment
Quick Start
CC
and
2) Connect the RF signal generator to the RFIN SMA
3) Connect a spectrum analyzer to the RFOUT SMA
4) Turn on the DC power supply. The supply current
5) Enable the RF generator’s output. The spectrum
A good printed-circuit board (PCB) is an essential part
of RF circuit design. The EV kit PCB can serve as a
guide for laying out a board using the MAX2659. Use
controlled impedance lines on all high-frequency inputs
and outputs. Bypass V
located close to the device. For long V
be necessary to add decoupling capacitors. Locate
these additional capacitors farther away from the
device package. This minimizes supply coupling.
Proper grounding of the GND pins is essential. Connect
the GND pins to the ground plane either directly, or
through vias, or both.
connector. Do not turn on the generator’s output.
Set the output of the RF signal generator to
1575.42MHz and power level to -40dBm.
connector.
1575.42MHz, reference level to 0dBm, and span to
1MHz.
should read approximately 4.1mA.
analyzer displays a tone at 1575.42MHz at approxi-
mately -20dBm.
Set
CC
the
with decoupling capacitors
center
Layout Issues
frequency
CC
lines, it may
to

Related parts for MAX2659EVKIT+