EVB-EMC1033 SMSC, EVB-EMC1033 Datasheet - Page 7

no-image

EVB-EMC1033

Manufacturer Part Number
EVB-EMC1033
Description
MCU, MPU & DSP Development Tools Evaluation Board
Manufacturer
SMSC
Datasheet

Specifications of EVB-EMC1033

Processor To Be Evaluated
EMC1033
Interface Type
USB
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
EMC1002/EMC1033/EMC1402 EVB User Manual
..
SMSC EMC1002/EMC1033/EMC1402
4 Demo Description
4.1
4.2
4.3
Register Manager Overview
Temperature History Graph
Temperature Limits and Alert/Therm2, Addr/Therm Outputs
The Register Manager application (RegMan) initially displays the main Help screen, where detailed
description of the application’s features may be found. The Help screens can be displayed at any time
by selecting Help from the menubar or pressing the ? button on the toolbar. RegMan enables the user
to display temperature readings, set temperature limits and read/write configuration register values.
To open a Temperature History Graph window, select Plot -> Temperature History Plot from the
menubar. The history plot continuously updates the temperature reported by the temp sensor. There
are several display options, including which temperatures to display (internal, external, external2 for
EMC1033 only), whether limits should be displayed, and if so, for which temp sensor. See a typical
Temperature History Graph in
The high and low limits are displayed as dashed lines, initially with values set in the EMC1002.ini file.
(or EMC1033.ini) These limits may be changed either in the register manager or by dragging the line
on the history plot. If any of the Temp High or Temp Low Limits are exceeded, the
will assert. If the Ext THERM Limit or the Local THERM Limit are exceeded, the
be asserted.
The
programmed limits. The state of these outputs can be monitored by the associated bi-color LEDs or
test points on the PCB.
The
Therm2
to clear the assert state. When configured as a
Response Protocol to clear the pin’s status. This pin is initialized as a
EMC1002/1033/1402 .ini file. Change register 0x09 bit #5 to “0” to configure the pin function to
mode.
Alert/Therm2
Alert/Therm2
output. When configured as an SMBus
and
output pin can be configured to function as either an SMBus
Addr
Figure 4.1 Temperature History Plot
/
Therm
Figure 4.1
outputs are asserted active Low when a temperature exceeds the
below:
7
Alert
Therm2
pin it will follow the SMBus Alert Response protocol
output it will not require the SMBus Alert
Therm2
Addr
Revision 1.1 (08-21-07)
Alert
Alert/Therm2
/
Therm
output or as a
output by the
output will
output
Alert

Related parts for EVB-EMC1033