Page 1
... Ampèrestrasse 3 9323 Steinach Switzerland with forcibly guided contacts according to EN50205 class A While Tyco Electronics and its affiliates referenced herein have made every reasonable effort to ensure the accuracy of the information contained herein, Tyco Electronics cannot assure that this information is error free. ...
Page 2
... Customer drawing NAME Product Specification Forcibly guided relay SR6 Department: RPG D&E Appl Version history -------- A1 10-07-05 ECR-NO.: Rev Date Table of content 1 Dimensions 2 Contact data 3 Coil data 4 General data 5 Insulation data 6 Type code 7 Approvals 8 Packaging 9 Customs Information 10 Quality complaint Attachment: Quality alert form Product data, technical parameters, test conditions and processing information only to be used together with the ‘ ...
Page 3
... Customer drawing NAME Product Specification Forcibly guided relay SR6 Department: RPG D&E Appl 1 Dimensions 1.1 Dimensional drawing (in mm) SR6 A/B/C SR6 V SR6 D/M 1.2 Mounting hole layout / Terminal assigment SR6 A Product data, technical parameters, test conditions and processing information only to be used together with the ‘Definitions’ section at http://relays.tycoelectronics.com/schrack/pdf/definitions.pdf © ...
Page 4
... Customer drawing NAME Product Specification Forcibly guided relay SR6 Department: RPG D&E Appl SR6 B SR6 C SR6 D SR6 M Product data, technical parameters, test conditions and processing information only to be used together with the ‘Definitions’ section at http://relays.tycoelectronics.com/schrack/pdf/definitions.pdf ©Tyco Electronics AMP 2158003 ...
Page 5
... Department: RPG D&E Appl SR6 V SR6 V allows clearance/creepage of 5 the pcb. Soldering terminals for PCB mounting. Square coil terminals width 0.5 x 0.5 mm. Rectangular contact terminals width 0.5 x 0.8 mm. All data without tin coating. The thickness of tin coating lies empirically in the range of 0.08 ... 0.2 mm. ...
Page 6
... Overload capacity ! Non Switching ! NO contact I²t value up to max. 450A for max contact I²t value up to max. 450 A for max 2.6.2 Short circuit protection acc. IEC60947-5-1 I Weld-free protection at NEOZED Fuse links, size D01; utilization category gL/gG acc.IEC60269-1; IEC60269-3-1; VDE036-T301 Rated fuse link current for NO contact Rated fuse link current for NC contact Product data, technical parameters, test conditions and processing information only to be used together with the ‘ ...
Page 7
... AC 15 2.7.1.3 UL contact rating B300 Pilot duty 2.7.1.4 AC Resistive loads (Power Factor 1.0) Standard IEC60947-4-1 AC-1 endurance 1NO contact switch cycle 0.1Hz, +70°C, Please note: The electrical endurance graph indicates the typical electrical endurance as "Mean Cycles to Failure" (MCTF) according to Weibull distribution. These statistical data do not guarantee a minimum value ...
Page 8
... Knut Dankert 24.06.2010 Frank Liebusch 05.07.2010 (cont.) Characteristically electrical endurance acc. IEC60947-5-1 DC-13 Ue=24VDC 10000000 1000000 100000 10000 Characteristically electrical endurance acc. IEC60947-5-1 DC-1 Ue=24VDC 10000000 1000000 100000 10000 SCHRACK REVISION Rated current [A] Ue 24V / Ie 6A 6,000 cycles Rated current [A] Page ...
Page 9
... Customer drawing NAME Product Specification Forcibly guided relay SR6 Department: RPG D&E Appl Electrical endurance and utilization category 2.7.2 Break contact (NC) 2.7.2.1 AC Inductive loads 2.7.2.2 AC Resistive loads (Power Factor 1.0) I =8A,U =250V , switch cycle 0.1Hz, +70° 1NC contact: 8A 2.7.2.3 DC Inductive loads 2 ...
Page 10
... SCHRACK REVISION Approved: Frank Liebusch 05.07.2010 DC, neutral, monostable 5...110 V DC typ. 800 Nom Nom Nom Nom Nom Nom 150 % of U Nom Nom 150 % of U Nom Nom Coil Rated coil resistance power 0.5 1190 21 10% 0.9 1200 120 10% 1 ...
Page 11
... Customer drawing NAME Product Specification Forcibly guided relay SR6 Department: RPG D&E Appl Electrical coil values continued Coil code Nominal Ordering code voltage (Block 4) VDC K12 12 K15 15 K18 18 K21 21 K24 24 All data are given for coil without preenergization and are measured with pulse shaping coil energization, at ambient temperature of +23° ...
Page 12
... Customer drawing NAME Product Specification Forcibly guided relay SR6 Department: RPG D&E Appl 3.7.2 Coil Operating Range DC (individual mounting >34mm) 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 0 -40 -30 - Minimum operate voltage without pre-energizing (cold coil) COLD U = Minimum Minimum operate voltage with 1 pre-energizing and rated contact current ...
Page 13
... Customer drawing NAME Product Specification Forcibly guided relay SR6 Department: RPG D&E Appl 3.7.3 Coil Operating Range DC (individual mounting >34mm) 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 0 -40 -30 - Minimum operate voltage without pre-energizing (cold coil) COLD U = Minimum Minimum operate voltage with 1 pre-energizing and rated contact current ...
Page 14
... Nom For use at – 40° C ... –25° not exceed the max. operating voltage of 120 % U No condensing or freezing allowed IEC 61810 can only be applied under standar- dized conditions. Application note SR6_AN_01 must be applied in all other cases. max. 100 ° (measured on PCB surface) ...
Page 15
... Product Specification Forcibly guided relay SR6 Department: RPG D&E Appl General data (cont.) 4.11 Vibration resistance (fault criterion according IEC 60068-2-6, Fc test NO contact (30 ... 500 Hz), NC contact (30 ... 500 Hz) 4.12 Shock resistance (fault criterion according IEC 60068-2-27, Ea test NO contact (half sinus, 11ms) NC contact (half sinus, 11ms) 4 ...
Page 16
... Customer drawing NAME Product Specification Forcibly guided relay SR6 Department: RPG D&E Appl 5 Insulation data (all values are measured at +23° C and 60% relative humidity) 5.1 According to IEC 61810-1 / IEC 60664-1 5.1.1 Rated voltage system 5.1.2 Rated insulation voltage 5.1.3 Pollution degree 5 ...
Page 17
... Customer drawing NAME Product Specification Forcibly guided relay SR6 Department: RPG D&E Appl 5.10 Clearance and creepage distances pole left / pole right Creepage: 9.7mm contact Clearance: 7.65mm contact outside Clearance & Creepage: 6mm contact Clearance: 6.5mm Product data, technical parameters, test conditions and processing information only to be used together with the ‘Definitions’ section at http://relays.tycoelectronics.com/schrack/pdf/definitions.pdf © ...
Page 18
... Product data, technical parameters, test conditions and processing information only to be used together with the ‘Definitions’ section at http://relays.tycoelectronics.com/schrack/pdf/definitions.pdf ©Tyco Electronics AMP 2158003 DWG NO: SR6_Spec OPTIONAL NO Drawer: Approved: Knut Dankert 24.06.2010 Frank Liebusch 05.07.2010 TÜVRheinland, No. 968/EL 350.05/09 Licence Nr. 128935 UL File E214024 COC 06017015576 / COC 06017015577 SCHRACK REVISION Page ...
Page 19
... Product data, technical parameters, test conditions and processing information only to be used together with the ‘Definitions’ section at http://relays.tycoelectronics.com/schrack/pdf/definitions.pdf ©Tyco Electronics AMP 2158003 DWG NO: SR6_Spec OPTIONAL NO Drawer: Approved: Knut Dankert 24.06.2010 Frank Liebusch 05.07.2010 620 x 27 665 x 170 x 115 mm Czech Republic General Purpose Relay 110/230VAC SCHRACK REVISION A1 10 pcs 0.325kg 25 / 250 pcs 8.50 kg ...
Page 20
... X Please cross that which does apply. 4. Product Returns Prior to returning products to Tyco Electronics, please contact the Customer Service Representative. Only Customer Service will provide authorization. You will receive: · ...