G6D-1A-ASI-NPDC24 Omron, G6D-1A-ASI-NPDC24 Datasheet - Page 2

no-image

G6D-1A-ASI-NPDC24

Manufacturer Part Number
G6D-1A-ASI-NPDC24
Description
NON-PARAFFIN COIL
Manufacturer
Omron
Series
G6D-ASIr
Datasheet

Specifications of G6D-1A-ASI-NPDC24

Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
5A
Switching Voltage
250VAC, 30VDC - Max
Turn On Voltage (max)
16.8 VDC
Turn Off Voltage (min)
2.4 VDC
Relay Type
General Purpose
Coil Type
Non Latching
Coil Current
8.3mA
Coil Voltage
24VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Features
Sealed - Fully
Contact Material
Silver Alloy
Operate Time
10ms
Release Time
5ms
Coil Power
200 mW
Coil Resistance
2.88K Ohms
Operating Temperature
-25°C ~ 70°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G6D1AASINPDC24
■ Coil Data
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%.
■ Characteristics
Note: Data shown are of initial value.
■ Characteristic Data
128
5
12
24
Contact resistance
Operate time
Release time
Operating
frequency
Insulation resistance
Dielectric strength
Surge withstand voltage
Vibration
Shock
Ambient temperature
Humidity
Life expectancy
Weight
Maximum Switching Capacity
0.5
0.3
0.1
50
30
10
5
3
1
voltage
0
2. Operating characteristics are measured at a coil temperature of 23°C (73°F).
3. The pick-up voltage is 75% or less of rated voltage if the relay is mounted upside down.
Rated
(VDC)
3
DC resistive
load
DC inductive
load
5
Power PCB Relay
Switching voltage (V)
10
40
16.7
8.3
30
AC inductive
load
cosφ=0.4
current
AC resistive load
100
Rated
(mA)
Mechanical
Electrical
Mechanical durability 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude
Malfunction durability 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude
Mechanical durability 1,000 m/s
Malfunction durability 100 m/s
Operating
Mechanical
Electrical
250 500 1,000
G6D-ASI
125
720
2,880
resistance
Coil
(Ω)
Life Expectancy
100 mΩ max.
10 ms max.
5 ms max.
18,000 operations/hour
1,800 operations/hour (under rated load)
1,000 MΩ min. (at 500 VDC)
3,000 VAC, 50/60 Hz for 1 minute between coil and contacts
750 VAC, 50/60 Hz for 1 minute between contacts of the same polarity
6,000 V, 1.20 x 50 μs between coil and contacts
-25° to 70°C (-13° to 158°F)
5% to 85% RH
20 million operations min. (at operating frequency of 18,000 operations/hour)
70,000 operations min. at rated loads (300,000 operations min for 2A at 250 VAC, 30 VDC,
resistive load)
Approx. 3 g (0.10 oz)
500
300
100
30
50
10
3
5
0
250-VAC/30 VDC inductive load
(cosφ=0.4/ L/R=7 ms)
1
2
70% max.
(approx. 10 G)
2
2
(approx. 100 G)
Switching current (A)
250-VAC/30-VDC resistive load
3
Pick-up
voltage
4
5
6
7
% of rated voltage
10% min.
8
9
Dropout
voltage
10
Ambient Temperature vs.
Maximum Coil Voltage
Note: The maximum coil voltage is the
200
180
160
140
120
100
80
60
0
160% at 23°C
maximum voltage that can be
applied to the relay coil.
23 30
Maximum
voltage
Ambient temperature (°C)
40
50
60
Approx. 200
consumption
70
Power
80
(mW)
90

Related parts for G6D-1A-ASI-NPDC24