G2R-1A-E-T130 DC24 Omron, G2R-1A-E-T130 DC24 Datasheet - Page 6

RELAY PWR SPST 16A 24VDC PCB

G2R-1A-E-T130 DC24

Manufacturer Part Number
G2R-1A-E-T130 DC24
Description
RELAY PWR SPST 16A 24VDC PCB
Manufacturer
Omron
Series
G2Rr

Specifications of G2R-1A-E-T130 DC24

Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
16A
Switching Voltage
380VAC, 125VDC - Max
Turn On Voltage (max)
16.8 VDC
Turn Off Voltage (min)
3.6 VDC
Relay Type
General Purpose
Coil Type
Non Latching
Coil Current
21.8mA
Coil Voltage
24VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
16A @ 250VAC
Control On Voltage (max)
16.8 VDC
Control Off Voltage (min)
3.6 VDC
Coil Voltage Vdc Nom
24V
Contact Current Max
16A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
1100ohm
Contact Configuration
SPST-NO
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G2R-1A-E-T130-DC24
G2R-1A-E-T130DC24
G2R-1A-E-T130DC24
G2R1AET130DC24
Z3123
G2R
Double-winding Latching Relays
Note:
I
UL 508 (File No. E41643)
6
Contact resistance
Set time
Reset time
Min. set/reset signal width
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
G2R-1
G2R-14
G2R-1-H
G2R-1-S
G2R-1-T
G2R-1A
G2R-1A4
G2R-1A-H
G2R-1A-S
G2R-1A-T
G2R-1-E
G2R-1A-E
G2R-2
G2R-24
G2R-2-H
G2R-2-S
G2R-2A
G2R-2A4
G2R-2A-H
G2R-2A-S
G2R-1A-ASI
Approved Standards
Values in the above table are the initial values.
*2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted.
Model
Item
SPDT
SPST-NO
SPDT
SPST-NO
DPDT
DPST-NO
SPST-NO
30 m
20 ms max.
20 ms max.
30 ms max.
Mechanical:18,000 operations/hr
Electrical:
1,000 M
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts
of same pole;
1,000 VAC, 50/60 Hz for 1 min between set and
reset coil
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: Set: 500 m/s
Reset:
Mechanical: 10,000,000 operations min (at 18,000 operations/hr)
Electrical:
Operating: 40°C to 70°C (with no icing)
Operating: 5% to 85%
Approx. 17 g
Contact form
max.
min. (at 500 VDC)
1,800 operations/hr (under rated load)
100,000 operations min. (at 1,800 operations/hr under rated load)
100 m/s
2
1 pole
(approx. 10G)
2
3 to 110 VDC
3 to 240 VAC
(approx. 100G)
2
Coil ratings
(approx. 50G); 200m/s
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
16 A, 30 VDC (resistive, NO contact only)
16 A, 250 VAC (general use, NO contact only)
TV-3 (NO contact only); 1/3 hp, 120 VAC
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
10 A, 250 VAC (general use)
TV-5/TV-8 (NO contact only)
10 A, 30 VDC (resistive)
2
50 m
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts
of different poles
1,000 VAC, 50/60 Hz for 1 min between contacts
of same pole
1,000 VAC, 50/60 Hz for 1 min between set and
reset coil
(approx. 20G)
max.
Contact ratings
2 poles
G2R

Related parts for G2R-1A-E-T130 DC24