RECT BRIDGE 3-PHA 1200V 35A D-63

36MT120

Manufacturer Part Number
36MT120
Description
RECT BRIDGE 3-PHA 1200V 35A D-63
Manufacturer
Vishay
Datasheets

Specifications of 36MT120

Voltage - Peak Reverse (max)
1200V
Current - Dc Forward (if)
35A
Diode Type
Three Phase
Speed
Standard Recovery >500ns, > 200mA (Io)
Mounting Type
QC Terminal
Package / Case
D-63
Product
Three Phase Bridge
Peak Reverse Voltage
1200 V
Forward Continuous Current
500 A
Max Surge Current
475 A
Forward Voltage Drop
1.19 V
Maximum Reverse Leakage Current
100 mA
Power Dissipation
0.35 W
Maximum Operating Temperature
+ 150 C
Length
28.5 mm
Width
28.5 mm
Height
10 mm
Mounting Style
Stud
Minimum Operating Temperature
- 55 C
No. Of Phases
Three
Repetitive Reverse Voltage Vrrm Max
1.2kV
Forward Current If(av)
35A
Forward Voltage Vf Max
1.19V
Operating Temperature Range
-55°C To +150°C
Phase Type
Three Phase
Number Of Elements
1
Peak Rep Rev Volt
1.2kV
Peak Non-repetitive Surge Current (max)
500A
Avg. Forward Curr (max)
35A
Rev Curr
200uA
Operating Temp Range
-55C to 150C
Pin Count
5
Mounting
Through Hole
Operating Temperature Classification
Military
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Reverse Recovery Time (trr)
-
Lead Free Status / Rohs Status
Compliant
Other names
*36MT120
VS-36MT120
VS-36MT120
VS36MT120
VS36MT120

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
36MT120
Manufacturer:
VIR
Quantity:
6
Part Number:
36MT120
Manufacturer:
IR
Quantity:
6
Part Number:
36MT120
Manufacturer:
PRX
Quantity:
726
Part Number:
36MT120
Manufacturer:
VISHAY/威世
Quantity:
20 000
www.irf.com
150
130
110
450
400
350
300
250
200
150
100
90
70
50
Number Of Equal Amplitude Half Cycle Current Pulses (N)
Fig. 9 - Maximum Non-Repetitive Surge Current
0
1
Fig. 6 - Current Ratings Characteristics
36MT.. Series
At Any Rated Load Condition And With
Rated V
5
80
70
60
50
40
30
20
10
0
0
10
Total Output Current (A)
36MT.. Series
T = 150°C
RRM
J
5
15
Applied Following Surge.
Total Output Current (A)
10
20
10
36MT.. Series
@ 60 Hz 0.0083 s
@ 50 Hz 0.0100 s
Initial T = 150°C
25
(Rect)
(Rect)
15
120°
120°
30
Fig. 8 - Total Power Loss Characteristics
J
20
35
25
100
40
30
35
0
Maximum Allowable Ambient Temperature (°C)
25
1000
50
100
500
450
400
350
300
250
200
150
100
Fig. 10 - Maximum Non-Repetitive Surge Current
10
1
0.01
0
Fig. 7 - Forward Voltage Drop Characteristics
75
36MT.. Series
Maximum Non Repetitive Surge Current
Instantaneous Forward Voltage (V)
36MT.. Series
0.5
100
Pulse Train Duration (s)
1
26MT../36MT.. Series
Bulletin I2771 rev. G 09/06
Versus Pulse Train Duration.
1.5
125
T = 15O°C
T = 25°C
Rated V
J
J
0.1
No Voltage Reapplied
2
Per Junction
150
Initial T = 150°C
2.5
RRM
3
Reapplied
J
3.5
5
1
4

Related parts for 36MT120