EFO-H418MS12 Panasonic - ECG, EFO-H418MS12 Datasheet - Page 6

SAW RESONATOR 418.0MHZ 1PORT

EFO-H418MS12

Manufacturer Part Number
EFO-H418MS12
Description
SAW RESONATOR 418.0MHZ 1PORT
Manufacturer
Panasonic - ECG
Series
EFO-Hr
Type
SAWr
Datasheet

Specifications of EFO-H418MS12

Frequency
418MHz
Features
Built in Capacitor
Frequency Stability
-150 ~ 50ppm
Impedance
30 Ohm
Capacitance
2pF
Operating Temperature
-20°C ~ 80°C
Mounting Type
Through Hole
Package / Case
Metal Can - 3 Lead
Size / Dimension
0.358" Dia x 0.138" H (9.10mm x 3.50mm)
Height
0.138" (3.50mm)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
EFOH418MS12
PX418S1
1. Electrostatic Discharge. The SAW filters and SAW
2. Grounding of the Equipment. Direct
3. Operating Temperature Range. The SAW filters and
4. R.F. Input Power. The SAW filters and resonators shall
5. Application of DC Voltage. Application of DC voltage to
Application Example (cont’d)
Local Oscillation Circuit
(Local Oscillation Circuit for Receiver)
Application Notes
resonators, which have extremely narrow spacings
between their interdigitated electrodes, shall be free from
high voltage spikes such as “Electrostatic Discharges,” to
prevent failures and damages of the devices. The
following countermeasures are recommended: (a)
ground human body via earth band; (b) set electricity
rejecting sheet to working table.
impression/application of line voltage to the SAW filters
and resonators shall cause short circuits between their
interdigitated electrodes.
resonators shall not be operated beyond the specified
“Operating Temperature Range” in the catalog and the
specifications.
not be operated beyond the specified “Maximum R.F.
Input Power Ratings” listed in specifications.
the SAW filters and resonators shall cause failures and
deterioration of the devices. DC voltage shall be cut by a
capacitor.
2SC3356
Saw Resonator
Design and specifications are subject to change without notice. Ask factory for technical specifications before purchase and/or use.
Whenever a doubt about safety issues arises from this product, please inform us immediately for technical consultation.
2pF
2SC2223
330 k
Vcc
Local Oscillation Output
6. Abnormal Mechanical Stresses. Abnormal/excess
7. Ultrasonic Cleaning. Ultrasonic cleaning may cause
8. Soldering to the Metallic Cases. The metallic cases of
9. Operating and Storage Conditions. The SAW filters and
mechanical stress such as pulling or bending forces shall
not be applied to the SAW filters and resonators for
preventing failures and damages of the devices.
deterioration and damage in mechanical and electrical
characteristics of the devices, and shall not be applied to
the SAW filters and resonators.
the SAW filters and resonators shall not be soldered for
the purpose of grounding. Soldering to the metallic cases
may cause deterioration or damage in mechanical and
electrical characteristics.
resonators shall not be operated and stored under the
following environmental conditions: (a) exposed directly
to water or salt water; (b) exposed directly to sunlight; (c)
under conditions of humidity and dust; (d) under
conditions of corrosive atmosphere such as hydrogen
sulfide, sulfurous acid, chlorine, or ammonia.
SAW Resonators