1394462-3 TE Connectivity, 1394462-3 Datasheet - Page 29

SOCKET, SOLARLOK, 4MM , POS

1394462-3

Manufacturer Part Number
1394462-3
Description
SOCKET, SOLARLOK, 4MM , POS
Manufacturer
TE Connectivity
Type
Powerr
Series
SolarLokr
Datasheets

Specifications of 1394462-3

Gender
F
Contact Material
Copper Zinc
Contact Plating
Silver
Body Orientation
Straight
Housing Material
Polyphenylene Oxide
Number Of Contacts
1POS
Number Of Ports
1Port
Number Of Terminals
1
Current Rating (max)
25A
Pitch (mm)
Not Requiredmm
Operating Temp Range
-40C to 105C
Mounting Style
Through Hole
Termination Method
Solder
Connector Type
Photovoltaic
Contact Termination
Crimp
No. Of Contacts
1
Connector Mounting
Cable
Colour
Black
Rohs Compliant
Yes
Coded, Keyed
Plus
Features
12 AWG
Product Type
Connector
Insulation Diameter (mm [in])
5.50 - 8.00 [.216 - .315]
Type Of Connector
Cable Coupler
Wire Size (mm² [awg])
4.0² [12]
Keying
Plus
Contact Base Material
Copper Zinc
Contact Finish
Silver Plate
Housing Color
Black
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Packaging Quantity
100
Lead Free Status / RoHS Status
Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Compliant
3.4 DC/AC Converter Receptacle
SOLARLOK Interconnection System
Assembly and Installation Guidelines
1 Place a single wire seal onto the wire and strip wire
2 Crimp the contact using the correct applicator for the wire gauge (# 114-74013)
3 Place O-ring onto the connector housing; push in wire to stop until contact locks into the housing
4 Push seal into the housing
5 Assembly of the cover cap (not available with every version) and mounting in front panel
All specifications subject to change. Consult Tyco Electronics for latest specifications.
(single wire seals are not available with every version).
Required panel mount hole diameter: Diameter 12.5 mm.
The panel thickness must not be under 1.0 mm.
For environmental protection of the unmated connector, use of the covering cap is recommended.
Cover:
Part No. 1394739-1
(continued)