E3JU-XRM4T-MN1 Omron, E3JU-XRM4T-MN1 Datasheet - Page 6

no-image

E3JU-XRM4T-MN1

Manufacturer Part Number
E3JU-XRM4T-MN1
Description
Photoelectric Sensors - Industrial F.O. 2mm DIA RLY TMR MINI CON
Manufacturer
Omron
Series
E3JUr
Datasheet

Specifications of E3JU-XRM4T-MN1

Sensing Distance
-
Sensing Method
-
Sensing Object
-
Output Configuration
Relay - Dark-ON/Light-ON - Selectable
Sensing Light
Red
Mounting Type
Bracket Mount
Current - Supply
-
Voltage - Supply
12 V ~ 240 V
Package / Case
Module, Connector
Features
Universal AC/DC Supply Voltage
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Diffuse Reflective Type
#
#
#
#
E3JU-X/XR
J SENSITIVITY ADJUSTMENT
J FIBER CONNECTION AND DISCONNECTION
6
E3JU-Xj4j-j
#
#
#
#
#
Place the target object in the desired position for
detection and set the sensitivity adjustment to maximum.
Maximum stability is achieved by varying both horizontal
and vertical alignment of the fiber until it is in the center of
a range in which both the LIGHT (Red) and STABILITY
(Green) indicators illuminate (Light-ON mode).
Remove the object and ensure the LIGHT indicator turns
off and the STABILITY indicator illuminates. If the LIGHT
indicator does not turn off, decrease the sensitivity and
check that there is no other object in line with the fiber.
Ensure the STABILITY indicator illuminates in both
detecting and non-detecting states. (Refer to table below.)
Uses E32 series fiber-optic cable with grooved tip
(4.75 mm diameter).
Make sure the clamp is raised in the unlocked position.
Firmly insert the fiber-optic cable tips into the amplifier.
Move the clamp down to the locked position (the ridges in
the clamp should slide into the grooves of the tips and
hold the fiber cables in place).
To remove the fiber cables, raise the clamp to the
unlocked position and carefully pull the fiber cables out
of the unit.
Diffuse
Object
Indicators
Light
(Red)
Stability
(Green)
Output
(Yellow)
LED Status (Light-ON Mode)
Incident
ON
ON
ON
Interrupt
OFF
ON
OFF
Through-beam Type
#
#
#
#
#
E3JU-XRj4j-j
#
#
#
Caution: The amplifier may be damaged if excessive force is
used when inserting the fiber cables.
#
#
Turn the sensitivity adjustment to maximum.
Position the fiber optic cable ends opposite each other and
adjust the horizontal and vertical alignment until the
STABILITY indicator (Green), LIGHT indicator (Red), and
OUTPUT indicator (Yellow) turn on (Light-ON mode).
Once the desired position is set, introduce the object to the
beam pattern and ensure that the LIGHT and OUTPUT
indicators turn off and the STABILITY indicator illuminates.
If the LIGHT and OUTPUT indicators do not turn off,
decrease the sensitivity until the desired result is achieved.
Ensure that the STABILITY indicator illuminates in both
detecting and non-detecting states. (Refer to table below.)
Uses E32 series fiber-optic cable (2.2 mm diameter or
1 mm diameter with E39-F9 adapter).
Make sure the clamp is placed in the unlocked position
Carefully insert the fiber cable into the amplifier, approxi-
mately 14.0 mm (0.55 in).
Rotate the clamp to the locked position to secure the fiber
cables in place.
To remove the fiber cables, rotate the clamp to the
unlocked position and carefully pull the fiber cables out
of the unit.
Through-beam
Object
E3JU-X/XR

Related parts for E3JU-XRM4T-MN1