E3S-CD11 Omron, E3S-CD11 Datasheet - Page 13

Photoelectric Sensors - Industrial DIFFUSE REFLECTIVE

E3S-CD11

Manufacturer Part Number
E3S-CD11
Description
Photoelectric Sensors - Industrial DIFFUSE REFLECTIVE
Manufacturer
Omron
Type
Long Range Metal Body Sensorr
Series
E3S-Cr
Datasheet

Specifications of E3S-CD11

Features
Mutual interference protection
Height
25.2 mm
Length
50 mm
Maximum Operating Temperature
+ 55 C
Minimum Operating Temperature
- 25 C
Operating Supply Voltage
10 V to 30 V
Width
20.4 mm
Sensing Distance
70 cm
Output Configuration
NPN or PNP
Output Current
100mA
Supply Voltage Range Dc
10V To 30V
Sensing Range Max
700mm
Sensor Housing
Rectangular
Switch Terminals
Wire Leaded
Sensor Input
Optical
Sensing Method
Reflective, Diffuse
Sensing Object
White Paper
Sensing Light
Infrared
Mounting Type
Bracket Mount, Horizontal
Current - Supply
40mA
Voltage - Supply
10 V ~ 30 V
Package / Case
Module, Connector
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E3S-CD11
Manufacturer:
OMRON
Quantity:
463
Precautions
J CONNECTION
If the input/output lines of the photoelectric sensor are placed in the
same conduit or duct as power lines or high-voltage lines, the photo-
electric sensor could be induced to malfunction, or be damaged, by
the electrical noise. Either separate the wiring, or use shielded lines
as input/output lines to the photoelectric sensor.
The cord connected to the E3S-C can be extended up to 100 m pro-
vided that the diameter of each wire of the cord is 0.3 mm
J POWER SUPPLY
If the standard switching regulator is used as a power supply, the
frame ground (FG) terminal and the ground (G) terminal, on the
power supply, must be grounded. If this is not done the E3S-C may
malfunction, due to the switching noise of the power supply.
If an inverter motor or servomotor is used with the E3S-C, the frame
ground (FG) terminal and the ground (G) terminal, on the motor,
must be grounded, otherwise the E3S-C may malfunction.
Installation
J MOUNTING
Use M4 screws to mount the E3S-C. The tightening torque of each
screw must be 12 kgf S m (1.18 N S m) maximum.
J DIRECT MOUNTING
Mount the E3S-C as shown in the following illustrations.
E3S-C
M4
M4 hole
M4 hole
Two, M3
Two, 4.5 dia.
through holes
M4 hole
M4 hole
M3
2
minimum.
J WATER RESISTANCE
To ensure the water resistance of the E3S-C, tighten the screws of
the operation panel cover to a torque of 3.5 to 5.5 kgf S cm (0.34 N S
m to 0.54 N S m).
J OPTICAL AXIS OF THROUGH-BEAM
The E3S-C through-beam models incorporate two lenses, one of
which will be used as shown in the following illustration. When using
a slit, the slit must be on the side where the lens is located.
SENSOR
Lens in use. The slit
must be on this side.
Lens not in use.
E3S-C