Specifications of E3G-MR19T-US

Features
Light ON / Dark ON
Maximum Operating Temperature
+ 55 C
Minimum Operating Temperature
- 25 C
Operating Supply Voltage
12 V to 240 V
Sensing Distance
10000 mm
Output Configuration
Relay
Sensing Method
Retroreflective
Sensing Object
Mirror
Sensing Light
Red
Mounting Type
Bracket Mount
Current - Supply
-
Voltage - Supply
12 V ~ 240 V
Package / Case
Module, Terminal Block
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
● Wiring
Recommended Example
• The cable with an external diameter of 6 to 8 mm is recommended.
• Be sure to attach the cover with screws securely in order to
• Do not tighten the Terminal Protection Cover with wires pinched
• Changing to Side-pullout Cable from Vertical-pullout Cable
Proce-
maintain the water- and dust-resistive properties of the product.
The size of the conduit opening is PF1/2 in accordance with JIS
B0202.
between the Sensor and the cover in order to maintain the water-
and dust-resistive properties of the product.
dure
1
2
3
4
33 mm
4
E3G-M@(T)
63 mm
Remove the present cover.
Attach the E39-L129 Terminal Protection Cover for side-
pullout cable.
Remove the clamping nut, washer, and rubber bushing of
the E3G. These are used for the side-pullout cable.
Attach the rubber bushing and cap provided with the
E39-L129 to the E3G as replacements.
4
5
Power supply
1Tc
2Ta
3Tb
Rubber bushing*
Cap*
*Not provided with UL-compliant (-US) models.
Output
1
2
3
Operation
*Provided with the E39-L129.
Rubber bushing*
Washer*
Clamping nut*
2
Rubber bushing
Washer
E39-L129 Terminal
Protection Cover
Terminal protection cover
Clamping nut
● Designing
Load Relay Contact
If E3G is connected to a load with contacts that spark when the load
is turned OFF (e.g., a contactor or valve), the normally-closed side
may be turned ON before the normally-open side is turned OFF or
vice-versa. If both normally-open output and normally-closed output
are used simultaneously, apply an surge suppressor to the load.
Refer to OMRON’s PCB Relays Catalog (X33) for typical examples of
surge suppressors.
● Wiring
Connecting and Wiring
The E3G has a built-in function to protect the E3G from load
shortcircuiting. If load shortcircuiting results, the output will be turned
OFF. In that case, check the wiring and turn ON the E3G again so that
the short-circuit protection circuit will be reset. This function will
operate if the output current flow is at least 2.0 times the rated load
current. If a capacitive load is connected to the E3G, make sure that
the inrush current does not exceed 1.2 times the rated load current.
● Mounting
Mounting Conditions
● Water Resistance
Tighten the operation cover screws and terminal block cover screws
to a torque of 0.3 to 0.5 N·m in order to ensure water resistivity.
• If Sensors are mounted face-to-face, make sure that no optical
• Be sure to install the Sensor carefully so that the directional angle
• Do not strike the Photoelectric Sensor with a hammer or any other
• Use M4 screws to mount the Sensor.
• When mounting the case, make sure that the tightening torque
axes cross each other. Otherwise, mutual interference may result.
range of the Sensor will not be directly exposed to intensive light,
such as sunlight, fluorescent light, or incandescent light.
tool during the installation of the Sensor, or the Sensor will loose its
water-resistive properties.
applied to each screw does not exceed 1.2 N·m.
All E3G Models