D-436-77 Tyco Electronics, D-436-77 Datasheet - Page 2

no-image

D-436-77

Manufacturer Part Number
D-436-77
Description
CONN SPLICE PARA 779-2680CMA
Manufacturer
Tyco Electronics
Datasheet

Specifications of D-436-77

Terminal Type
Inline, Individual Openings (Parallel)
Number Of Wire Entries
Varies by Wire Size
Termination
Crimp
Wire Gauge
779-2680 CMA
Insulation
Fully Insulated
Features
Heat Shrink
Color
Blue, Blue Stripe
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
3-1195132-8
650100-000
APPLICATION
1. These parts are designed to provide an immersion resistant stub splices made with wires having insulations rated
2. Part will seal assemblies which require insertion of not more than two wires per hole of the inserts. If two wires
3. Recovered dimensions of insulation sleeve: I.D – 3.18 (0.125) max
INSTALLATION PROCEDURE:
1. Pass wires to be crimped through the holes of the multi-holed insert (NOT MORE THAN TWO WIRES
2. Strip wires 7.94 to 8.73 (5/16” to 11/32”).
3. Insert wires into crimp splicer leaving a gap of 0.79 (1/32”) between the wire insulation and the barrel.
4. Crimp using a Raychem AD-1377 Crimp Tool or equivalent
5. Slide sleeve as close as possible to the crimp barrel. Hold sleeve in this position by squeezing the wires directly
6. Apply heat as follows:
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS.
INCHES DIMENSIONS ARE BETWEEN BRACKETS.
TOLERANCES:
0.00 N/A
0.0 N/A
0 N/A
DRAWN BY:
If this document is printed it becomes uncontrolled. Check for the latest revision.
for at least 135 C.
are inserted through one hole, they must be of same gauge size.
THROUGH ANY HOLE). Care must be taken to avoid twisting of the wires as this will prevent proper
behind it.
positioning of the sleeve.
M. FORONDA
a) Use a Raychem Model 500A Thermogun, equipped with a TG-14A reflector.
b) Adjust side vent of Thermogun to give an air-stream temperature of 650 – 750 F.
c) Center assembly in the reflector well long enough to cause the center section of the sleeve to recover and lock
d) Move assembly to position the top (major wire entry end) in the hot air-stream. Hold in this position until insert
e) Apply heat to bottom of sleeve until insert melts and flows.
f)
itself in place.
has completely melted and flowed axially along the wires.
The total time required to install the sealing sleeve is dependent upon the air-stream temperature and mass of the
crimped assembly being encapsulated.
ANGLES: N/A
ROUGHNESS IN
MICRON
REPLACES:
Menlo Park, CA 94025, USA
Tyco Electronics Corporation
305 Constitution Drive
Tyco Electronics reserves the right to amend this
drawing at any time. Users should evaluate the
suitability of the product for their application.
N/A
SPECIFICATION CONTROL DRAWING
Wall – 0.33 (0.013) min
DCR NUMBER:
D001300
Raychem
Products
DOCUMENT NO.:
DATE:
PROD. REV.
SEE TABLE
05-Dec.-00
D-436-77/-78
TITLE :
SCALE:
None
STUB SPLICE SEALING
SYSTEM MULTI-WIRE
SIZE:
A
DOC ISSUE:
1
SHEET:
2 of 2

Related parts for D-436-77