MAX6965ATE Maxim Integrated Products, MAX6965ATE Datasheet - Page 13

no-image

MAX6965ATE

Manufacturer Part Number
MAX6965ATE
Description
LED Drivers
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6965ATE

Number Of Segments
6
Operating Supply Voltage
2 V to 3.6 V
Maximum Supply Current
110 uA
Maximum Power Dissipation
1176 mW
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Package / Case
TQFN-16
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 6. Blink Phase 0 Register
Table 7. Blink Phase 1 Register
Table 8. PWM Application Scenarios
All outputs static without PWM
A mix of static and PWM outputs, with PWM
outputs using different PWM settings
A mix of static and PWM outputs, with PWM
outputs all using the same PWM setting
All outputs PWM using the same PWM
setting
Read-back outputs phase 0
Read-back outputs phase 1
Write outputs phase 0
Write outputs phase 1
APPLICATION
9-Output LED Driver with Intensity Control
REGISTER
REGISTER
______________________________________________________________________________________
R/W
R/W
Set the master, O8 intensity register 0x0E to any value from 0x00 to 0x0F.
The global intensity G bit in the configuration register is don't care.
The output intensity registers 0x10 through 0x13 are don't care.
Set the master, O8 intensity register 0x0E to any value from 0x10 to 0xFF.
Clear global intensity G bit to 0 in the configuration register to disable global intensity
control.
For the static outputs, set the output intensity value to 0xF.
For the PWM outputs, set the output intensity value in the range 0x0 to 0xE.
As above. Global intensity control cannot be used with a mix of static and PWM
outputs, so write the individual intensity registers with the same PWM value.
Set the master, O8 intensity register 0x0E to any value from 0x10 to 0xFF.
Set global intensity G bit to 1 in the configuration register to enable global intensity
control.
The master, O8 intensity register 0x0E is the only intensity register used.
The output intensity registers 0x10 through 0x13 are don't care.
0
1
0
1
ADDRESS
ADDRESS
and Hot-Insertion Protection
CODE
CODE
(hex)
(hex)
0x01
0x09
OP7
OP7
D7
D7
RECOMMENDED CONFIGURATION
OP6
OP6
D6
D6
OP5
OP5
D5
D5
REGISTER DATA
REGISTER DATA
OP4
OP4
D4
D4
OP3
OP3
D3
D3
OP2
OP2
D2
D2
OP1
OP1
D1
D1
OP0
OP0
D0
D0