LDS8866002-T2-300/300/300 Leadis Technology, LDS8866002-T2-300/300/300 Datasheet - Page 7

LED Drivers 6Ch Chrg Pump w/1.33 Mode, PwrLite Reg

LDS8866002-T2-300/300/300

Manufacturer Part Number
LDS8866002-T2-300/300/300
Description
LED Drivers 6Ch Chrg Pump w/1.33 Mode, PwrLite Reg
Manufacturer
Leadis Technology
Datasheet

Specifications of LDS8866002-T2-300/300/300

High Level Output Current
180 mA
Operating Supply Voltage
2.7 V to 5.5 V
Maximum Supply Current
2.5 mA
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
TQFN-16
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
LDS8866
difference between the input voltage when exiting 1-x
mode and returning to 1-x mode is called the 1-x
mode transition hysteresis (about 600 mV).
Operation of PWM-based LED Current Control
The maximum current value in each of the
LDS8866’s three LED banks is factory preset; to set
each ILED below this value, a PWM (a duty cycle
based) control signal can be applied at the
PWM1/PWM2 pins.
WLED color temperature over a wide range of LED
currents. The LED color temperature set at the
factory preset maximum LED current does not vary
with respect to the average LED current unlike
conventional 1-wire LED current control methods.
Note:
Timing diagram represents condition when LED forward voltage Vf is higher than Charge Pump Mode times(1.5) input voltage minus voltage
drop on current regulator VPCR and minus voltage drop on charge pump output resistance Rcp at Iled current through N LEDs.
Vf > CPM X Vin – Vd – Rcp x Iled x N; PWM duty Cycle = T
When LED current control is enabled at the
PWM1/PWM2 inputs, the LDS8866’s maximum input
current is determined by the factory preset maximum
LED current multiplied by number of LED used, the
© 2008 Leadis Technology
Characteristics subject to change without notice
Using a PWM control technique guarantees stable
Figure 3. LDS8866 Timing Diagram
PWM ON
/ (T
7
PWM ON
+ T
The LDS8866’s PWM logic control circuits have been
designed to operate from 100 Hz to 100 kHz with
duty cycles higher than (0.02*F)% and lower than
(100 – 0.02*F)%, where F is the PWM control
frequency in kHz. The brightness dynamic dimming
range at 200 Hz is 25,000 : 1. PWM control
frequencies lower than 100 Hz are not recommended
(especially with short duty cycles) because LED
flicker may become visible.
When PWM current control is enabled, the LED
current is modulated from zero to 100% over a single
PWM period. For example, when PWM1/PWM2 is
logic high, the LED current is set equal to the
maximum factory preset value. When PWM1/PWM2
is logic low, the LED current is zero. The average
LED current level is then determined by the PWM
duty cycle that may be adjusted as described above.
charge pump operating mode (1-x, 1.33-x, 1.5-x, or
2-x), and divided by charge-pump driver’s efficiency.
For example, if six LEDs are used and the charge
pump is operating in 2-x mode, the maximum pulse
current at V
PWM OFF
)
IN
would then be 400 mA (= 30 mA/LED x
Doc. No. 8866DS, Rev. 2.0

Related parts for LDS8866002-T2-300/300/300