GLK19264-7T-1U-WBE Matrix Orbital, GLK19264-7T-1U-WBE Datasheet - Page 56

no-image

GLK19264-7T-1U-WBE

Manufacturer Part Number
GLK19264-7T-1U-WBE
Description
LCD Graphic Display Modules & Accessories Blue Background White Text/Ext Temp
Manufacturer
Matrix Orbital
Datasheet

Specifications of GLK19264-7T-1U-WBE

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
13.2 Set Remember
13.3 Data Lock
Matrix Orbital
Syntax
Parameters
Description
Remembered
Default
Syntax
Parameters
This command allows you to switch the remember function on and off.
To use the remember function, set remember to on, then set all of the
settings that you wish to save, settings that are listed as ’Remember:
Yes’ support being saved into the non-volatile memory. After you have
set all of the commands that you wish to save, you may then cycle the
power and check the display settings to ensure that all the settings have
been saved. If you wish to use remember again after cycling the power,
you must set it to on again.
NOTES
No
Do not remember
Hexadecimal
Decimal
Parameter
switch
Hexadecimal
Decimal
Parameter
level
• Writing to non-volatile memory is time consuming and slows down the operation of
• Non-volatile memory has a ‘write limit’ and may only be changed approximately
the display.
100,000 times.
GLK19264-7T-1U
0xFE 0x93 [switch]
254 147 [switch]
0xFE 0xCA 0xF5 0xA0 [level]
254 202 245 160 [level]
Length
Length
1
1
Description
0: Do not remember, 1: Remember
Description
Sets the data lock level
51