EAIC202-PGH ELECTRONIC ASSEMBLY, EAIC202-PGH Datasheet - Page 8

no-image

EAIC202-PGH

Manufacturer Part Number
EAIC202-PGH
Description
Display Modules & Development Tools Graphic Con RS-232 128x64 for HD61202
Manufacturer
ELECTRONIC ASSEMBLY
Datasheet

Specifications of EAIC202-PGH

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
EA IC202
DESCRIPTION OF VARIOUS GRAPHICS FUNCTIONS
The following pages show detailed descriptions in alphabetical order for each individual function.
Examples are shown as hardcopy in an enlarged window of 50 x 32 pixel once the command has been
executed. Examples show all transfered bytes in Hex code.
A
A character n1 will be displayed on coordinates x1,y1 with preset font 'F' and text
mode 'T' (setzen / löschen / invertieren / replace / invers replace / pattern). Origin is
(0,0) at top left hand corner of display. Datas for coordinates apply also to top left
hand corner of a given character. Note: Font No.1 shows capital letters only.
Example:
Character 'E' is displayed at coordinates 19,2
Preset font: 6x8, width 2x and height 2x
Text mode: Replace and black pattern
B
Up to 8 bargraphs (nr=1..8) can be defined, which may oscillate to L=left, R=right,
O=up or U=down direction. Bargraph full level range coordinates are described from
x1,y1 to x2,y2. Scaling of bargraph is performed by starting zero position aw
(=0..254) and max. ending position (full size) ew (=0..254). Bargraph always is
displayed in inverse-mode using the ptn-pattern type: the background remains
preserved in any case. (Note: executing this command only the bargraph range is
defined but nothing is visible on display).
Example:
Defines bargraph no. 1 which oscillates vertical up to top. At full level its coordinates ranges from 4,2 to 9,30.
Displayed start- and end values represent current values of 4..20 mA. (Hardcopy shows bargraph at its full level
operating at $42 $01 $14)
B
Bargraph number n1 (1..8) will be adjusted to a new value (aw <= value <= ew).
If value > ew, than final value will be displayed. Bargraph must be defined before,
see above example.
Example:
Above defined bargraph no. 1 is set now to value 10.
C
Switches display On (n1=1) or Off (n1=0); all display datas remains preserved and
commands can be executed furthermore.
Example:
Content of display becomes invisible, but remains preserved.
8
x1 y1 n1
L/R/O/U nr x1
nr value
n1
$41
$42
$42
$43
$13 $02
$4F $01
$01 $0A
$00
y1 x2 y2 aw ew ptn
$45
$04
$02
$09
$1E $04
$14
$01
Set ASCII-Characters
Define Bargraph
Display Control
Draw Bargraph

Related parts for EAIC202-PGH