416101300-3 Digital View Inc, 416101300-3 Datasheet

no-image

416101300-3

Manufacturer Part Number
416101300-3
Description
Display Modules & Development Tools RM-DN3 SWITCHMOUNT BOARD 8-BUTTON
Manufacturer
Digital View Inc
Datasheet

Specifications of 416101300-3

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Application Note
Button Connection on ViewStream Player
(for M3-100/VS-100/M3-300/VS-300/M3-320/VS-320/VS-500/VS-520/RM-DN5)
Version 2.1

Related parts for 416101300-3

416101300-3 Summary of contents

Page 1

Button Connection on ViewStream Player (for M3-100/VS-100/M3-300/VS-300/M3-320/VS-320/VS-500/VS-520/RM-DN5) Application Note Version 2.1 ...

Page 2

Table of Contents 1 Introduction ....................................................................................3 1.1 What you need? .......................................................................3 2 Button Connection ...........................................................................4 2.1 Connection with M3-100 & VS-100 .............................................4 2.1.1 Connect 8-button with M3-100 ..........................................4 2.1.2 Connect 8-button with VS-100...........................................5 2.2 Connection with M3-300 & VS-300 .............................................6 ...

Page 3

... For OEM player board M3-100, M3-300, M3-320 and RM-DN5 M3-100, M3-300, M3-320 or RM-DN5  9-ways button cable (P/N 426450100-3, 140mm or P/N 426450110-3,  300mm) Switch mount board (P/N 416101300-3)  For both you will need a copy of DV Studio which can be downloaded from: http://www.digitalview.com/products/software Page ...

Page 4

... Button Connection 2.1 Connection with M3-100 & VS-100 2.1.1 Connect 8-button with M3-100  Use the switchmount (P/N:416101300-3) for 1-8 buttons when connected to the button connector CN6 via the standard switchmount cable (P/N:426450100- Button # 8-button switch mount P/N: 416101300-3 8-button switch mount cable ...

Page 5

... Connect 8-button with VS-100 Use the switchmount (P/N:416101300-3) for 1-8 buttons when connected to the Remote Ext. socket (CN5) via the standard cable (P/N:426631800- 3) Important note: There is no additional button connector for #9 - #16 available on M3-100 and VS-100. 8-button switch mount cable (Remote Ext ...

Page 6

... Connection with M3-300 & VS-300 2.2.1 Connect 8-button with M3-300  Use the switchmount (P/N:416101300-3) for 1-8 buttons when connected to the button connector CN6 via the standard switchmount cable (P/N:426450100-3) 8-button switch mount cable (CN6) P/N: 42645 1100-3 CN5 IR2 ...

Page 7

... Use the switchmount (P/N:416101300-3) for 1-8 buttons when connected to the button connector CN6 via the standard switchmount cable (P/N:426450100-3)  Use the switchmount (P/N:416101300-3) for 9-16 buttons when connected to the button connector CN3 via the standard switchmount cable (P/N:426450100-3) Page ...

Page 8

... Connect 8-button with VS-300 Use the switchmount (P/N:416101300-3) for 1-8 buttons when connected to the Remote Ext. socket (CN5) via the standard cable (P/N:426631800 POWER STATUS Important note: There is no additional button connector for #9 - #16 available on VS-300. However possible to access button #9 - #16 on VS-300 but a custom-made housing design is required ...

Page 9

... Connection with M3-320 & VS-320 2.3.1 Connect 8-button with M3-320  Use the switchmount (P/N:416101300-3) for 1-8 buttons when connected to the button connector CN6 via the standard switchmount cable (P/N:426450100-3) Button # 8-button switch mount cable (CN6) P/N: 42645 1100-3 CN5 ...

Page 10

... Connect 16-button with M3-320  Use the switchmount (P/N:416101300-3) for 1-8 buttons when connected to the button connector CN6 via the standard switchmount cable (P/N:426450100-3)  Use the switchmount (P/N:416101300-3) for 9-16 buttons when connected to the button connector CN3 via the standard ...

Page 11

... Connect 8-button with VS-320 Use the switchmount (P/N:416101300-3) for 1-8 buttons when connected to the Remote Ext. socket (CN5) via the standard cable (P/N:426631800 POWER STATUS Important note: There is no additional button connector for #9 - #16 available on VS-320. However possible to access button #9 - #16 on VS-320 but a custom-made housing design is required ...

Page 12

... Connection with RM-DN5, VS-500 & VS-520 2.4.1 Connect 8-button with RM-DN5  Use the switchmount (P/N:416101300-3) for 1-8 buttons when connected to the button connector CN6 via the standard switchmount cable (P/N:426450100-3) Button #1 to Button #8 8-button switch mount P/N: 416101300 USB ...

Page 13

... Connect 16-button with RM-DN5  Use the switchmount (P/N:416101300-3) for 1-8 buttons when connected to the button connector CN6 via the standard switchmount cable (P/N:426450100-3)  Use the switchmount (P/N:416101300-3) for 9-16 buttons when connected to the button connector CN3 via the standard ...

Page 14

... Connect 8-button with VS-500 & VS-520  Use the switchmount (P/N:416101300-3) for 1-8 buttons when connected to the Remote Ext. socket (CN5) via the standard cable (P/N:426631800-3) REM O TE LAN EXT. SW1 HDMI 8-button switch mount cable (Remote Ext. cable, CN5) ...

Page 15

Playlist configuration For whatever type of buttons are used including the ITO touch screen type, each button function can be programmed with DV Studio to perform a video player mode function or specific track select function. The button control ...

Page 16

Playlist mode In playlist mode both a playlist file (.pll) and project file (.prj) are required. These are created by DV Studio. 3.2.1 Playlist Creation In the Button settings area, you are able to define the action events of ...

Page 17

We have pre-defined two button profiles (8 buttons and 16 buttons Studio. The following is the default settings in device function for these two profiles. 8 Buttons Profile Push button # 1 Push button # 2 Push button ...

Page 18

Pin Assignments 4.1 Button Circuit diagram The following circuit diagram illustrates each button connection on CN3, CN5 and CN6. SW 4.2 Switch and Button connector CN5 – Remote Ext. connector (#1 - #8) Pin 5 PIN SYMBOL 1 SW1 ...

Page 19

CN6 - Switches and buttons connector (#1 - #8) PIN SYMBOL 1 SW1 2 SW2 3 SW3 4 SW4 5 SW5 6 SW6 7 SW7 8 SW8 9 GND CN3 - Switches and buttons connector (#9 - #16) PIN SYMBOL ...

Page 20

... CONTACT DETAILS USA: Digital View Inc. 18440 Technology Drive Building 130 Morgan Hill, CA 95037 Tel: (1) 408-782 7773 Sales: ussales@digitalview.com EUROPE: Digital View Ltd 6 Marylebone Passage London W1W 8EX UK Tel: (44) (0)20 7631 2150 Sales: uksales@digitalview.com ASIA: Digital View Ltd th 16 floor Millennium City 3 ...