1721032 Phoenix Contact, 1721032 Datasheet - Page 2

CONN TERM BLOCK 5.00MM 3POS

1721032

Manufacturer Part Number
1721032
Description
CONN TERM BLOCK 5.00MM 3POS
Manufacturer
Phoenix Contact
Series
COMBICON MKKDSr
Type
Wire to Boardr
Datasheets

Specifications of 1721032

Terminal Block Type
Wire to Board
Number Of Levels
2
Positions Per Level
3
Pitch
0.197" (5.00mm)
Mating Orientation
Horizontal with Board
Current
10A
Voltage
300V
Wire Gauge
12-30 AWG
Mounting Type
Through Hole
Termination
Screw
Features
Side Stacking (Interlocking)
Color
Green
Product
Fixed Terminal Blocks
Number Of Positions / Contacts
3
Wire Gauge Range
24-12
Current Rating
22 A
Voltage Rating
250 V
Mounting Style
Through Hole
Mounting Angle
Straight
Termination Style
Screw
Flammability Rating
UL 94 V-0
Wire Gauge Max (awg)
12
Wire Gauge Min (awg)
24
Agency Approvals
UL, cULus, CSA
Brand/series
MKKDS
Cross-section Area
2.5 mm^2 (Nom.)
Current, Rating
22 A
Diameter, Hole
1.3 mm
Dimensions, Pin
0.9 x 0.9 mm
Length, Stripping
8 mm
Level
Double Level
Material, Insulation
PA
Number Of Poles
3 Poles
Phoenix Part Number
MKKDS 3/ 3
Pin Spacing
5 mm
Primary Type
PCB
Screw Thread
M 3
Special Features
with Offset Levels
Torque, Tightening
0.5 nm (Min.)
Voltage, Rating
250 V
Voltage, Surge
4 kV
Wire Entry
Front
Wire, Awg
24-12
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
277-1372
MKKDS 3/3
MKKDS 3/ 3
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1721032
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Number of positions
Pin dimensions
Hole diameter
Screw thread
Tightening torque, min
Tightening torque max
Technical data
Range of articles
Insulating material group
Rated surge voltage (III/3)
Rated surge voltage (III/2)
Rated surge voltage (II/2)
Rated voltage (III/3)
Rated voltage (III/2)
Rated voltage (II/2)
Connection in acc. with standard
Nominal current I
Nominal cross section
Maximum load current
Insulating material
Inflammability class acc. to UL 94
Internal cylindrical gage
Stripping length
Nominal voltage, UL/CUL Use Group B
Nominal current, UL/CUL Use Group B
Nominal voltage, UL/CUL Use Group D
Nominal current, UL/CUL Use Group D
Connection data
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section stranded min.
Conductor cross section stranded max.
Conductor cross section stranded, with ferrule
without plastic sleeve min.
N
Order No.: 1721032
3
0,9 x 0,9 mm
1.3 mm
M3
0.5 Nm
0.6 Nm
MKKDS 3
I
4 kV
4 kV
4 kV
250 V
400 V
630 V
EN-VDE
22 A
2.5 mm²
24 A (with 4 mm² conductor cross section)
PA
V0
A3
8 mm
125 V
15 A
300 V
10 A
0.2 mm²
4 mm²
0.2 mm²
2.5 mm²
0.25 mm²
Jun 11, 2011
Page 2 / 5