MCHP05W4F1003T5E MULTICOMP, MCHP05W4F1003T5E Datasheet - Page 3

RESISTOR, HIGH POWER, 100KOHM, 250mW, 1%

MCHP05W4F1003T5E

Manufacturer Part Number
MCHP05W4F1003T5E
Description
RESISTOR, HIGH POWER, 100KOHM, 250mW, 1%
Manufacturer
MULTICOMP
Series
HP05r
Datasheet

Specifications of MCHP05W4F1003T5E

Resistance
100kohm
Resistance Tolerance
± 1%
Power Rating
250mW
Voltage Rating
150V
Resistor Element Material
Thick Film
Temperature Coefficient
± 100ppm/°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Performance specification
Temperature coefficient
Short time overload
Terminal bending
Dielectric withstanding
voltage
Solderability
Soldering heat
Temperature cycling
Load life in humidity
Load life
HP05 Series High Power Resistors
Characteristics
≤ 10E: ±200PPM/°C
> 10E: ±100PPM/°C
Resistance change rate is
±5% (2.0% + 0.1Ω) maximum
±1% (1.0% + 0.1Ω) maximum
± (1.0% + 0.05Ω) maximum
No evidence of flashover mechanical
damage, arcing or insulation break down.
Minimum 95% coverage
Resistance change rate is
±(1%+0.05Ω) Maximum
±5% (1.0% + 0.05Ω) maximum
±1% (0.5% + 0.05Ω) maximum
Resistance change rate is
±5% (3.0% + 0.1Ω) maximum
±1% (1.0% + 0.1Ω) maximum
Resistance change rate is
±5% (3.0% + 0.1Ω) maximum
±1% (1.0% + 0.1Ω) maximum
Limits
Page <3>
Resistance change after continuous 5 cycles for duty
cycle specified below:
Natural resistance change per temperature degree
centigrade
R2-R1/ R1 (t2-t1) x 10
R1
R2
Test pattern
Permanent resistance change after the application of a
potential of 2.5 times RCWV for 5 seconds.
Clamped in the trough of a 90°C metallic V-BLOCK
and shall be tested at AC potential respectively
specified in the type for 60-70 seconds.
Test temperature of solder
Soldwe
Dip the resistor into a solder bath having a
temperatuer Of 260°C ±3°C and hold It for 10±1
seconds.
Twist of Test Board : Y/X = 3/90 mm for 60 seconds.
Resistance change after 1000 hours
(1.5 hours "on", 0.5 hour "off") at RCWV
in a humidity chamber controlled at
40°C ±2°C and 90 to 95% relative humidity.
Permanent resistance change after 1000 hours
operating at RCWV with duty cycle of
(1.5 hours "on", 0.5 hour "off") at 70°C ±2°C ambient.
Step
1
2
3
4
: Resistance value at room temperature (t1)
: Resistance value at room temperature plus
100°C (t2).
Temperature
-55°C ±3°C
Room temperature
+155°C ±2°C
Room temperature
Test Methods (JIS C 5201-1)
: Room temperature(t1),
Room temperature+100°C(t2)
6
(PPm/°C).
Time
30 minutes
10 to 15 minutes
30 minutes
10 to 15 minutes
: 245 ±3°C; dipping
: 2-3 seconds.
time in
02/05/08 V1.1

Related parts for MCHP05W4F1003T5E