3G3JV-PFI1010-E Omron, 3G3JV-PFI1010-E Datasheet - Page 7

no-image

3G3JV-PFI1010-E

Manufacturer Part Number
3G3JV-PFI1010-E
Description
FILTER, 0.1-0.4KW, 1 PHASE MOTOR
Manufacturer
Omron
Datasheet

Specifications of 3G3JV-PFI1010-E

Filter Type
EMI
Current Rating
10A
Svhc
No SVHC (15-Dec-2010)
External Depth
45mm
External Length / Height
169mm
External Width
71mm
No. Of Phases
1
Power Rating
0.55kW
Termination Type
Wire
Capacitance
0µF
Parameter
number
n001
n002
n003
n004
n005
n006
n007
n008
n009
n010
n011
n012
n013
n014
n015
n016
Set of Parameters
Default
setting
1
0
0
0
0
0
0
0
60.0 Hz
200 V
60.0 Hz
1.5 Hz
12 V
1.5 Hz
12 V
10.0s
MODBUS
address
101H
102H
103H
104H
105H
106H
107H
108H
109H
10AH
10BH
10CH
10DH
10EH
10FH
110H
Name
Parameter write prohibit selection/
parameter initialization
Operation mode selection
Frequency reference selection
Stop method
Backwards direction of rotation
Operator stop button
Reference value in local mode
Reference value input in
local mode
Maximum output frequency
Max. output voltage
Corner frequency
Middle output frequency
Output voltage at middle output
frequency
Minimum output frequency
Output voltage at minimum output
frequency
Acceleration time 1
Adjustment range
0
1
6
7
8
9
0
1
2
0
1
2
3
4
6
0
1
0
1
0
1
0
1
0
1
50,0..400 Hz
1..255 V
0,2..400 Hz
0,1..399,9 Hz
0,1..255 V
0,1..10 Hz
0.1..50 V
0,0..999 s
Only n01 can be adjusted
n01- -079 can be altered
reset error memory
not used
initializes parameters to default values in 2- -wire sequence
initializes parameters to default values in 3- -wire sequence
Operator console
Multifunction inputs
via modbus (option card needed)
integrated potentiometer
parameter n021
0..10 V
4..20 mA
0..20 mA
modbus (option card needed)
Stop at ramp (n017)
Coast to stop
Reverse enabled
Reverse disabled
Stop button at n02= 1 enabled
Stop button at n02= 1 disabled
integrated potentiometer
digital via operator (n024)
complete input with ENTER
no ENTER necessary
3G3JV inverter
19

Related parts for 3G3JV-PFI1010-E