567 (BOXED) 3M, 567 (BOXED) Datasheet

TERMINAL, WIRE TAP/SPLICE, CRIMP, BROWN

567 (BOXED)

Manufacturer Part Number
567 (BOXED)
Description
TERMINAL, WIRE TAP/SPLICE, CRIMP, BROWN
Manufacturer
3M
Series
Scotchlokr
Type
IDCr
Datasheets

Specifications of 567 (BOXED)

Connector Type
Wire Tap Splice
Insulator Color
Brown
Termination Method
Crimp
Wire Size (awg)
18-10
Contact Material
Brass
Contact Plating
Tin
Brand/series
Scotchlok™
Color
Brown
Insulation Type
Polypropylene
Length, Overall
1.33 "
Material, Contact
Brass
Number Of Contacts
2
Package Quantity
50⁄Box, 1000⁄Case
Primary Type
Tap
Termination
Wire
Width, Overall
0.83 "
Wire Size
18-14 AWG
Wire, Awg
18-14 (Tap), 12-10 (Run)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Scotchlok
Self-Stripping Electrical
Tap Connectors
Data Sheet
Application
Use Part No. 567 to electrically connect a (tap) wire
end to a through (run) wire and insulate the
connection.
Wire Range
(Tap) 18-14 AWG (.75-1.5 mm
(Run) 12-10 AWG (4.0 mm
Solid or stranded copper conductors. For use with
common thermoplastic insulated wires such as: T, TF,
TFF, TFN, TFFN, AWM, TEW, SAE-GPT with a
maximum insulation diameter of (tap) .145 inches (3.5
mm) run .190 inches (4.8 mm).
Maximum recommended current for general purpose
applications:
18 AWG - 7 AMPS, 16 AWG - 10 AMPS,
14 AWG-15 AMPS, 12 AWG-20 AMPS,
10 AWG-25 AMPS.
Construction
U-contact - Tin plated brass, .03 in. (.8 mm) thick
Insulator - Flame retardant polypropylene,
Weight
.0067 lb. (3.0 gm)
Color - brown
2
)
2
):
567
Recommended Installation Tools
9” Linemans Pliers
3M
Installation Instructions
1. Place unstripped run wire inside run channel.
2. Insert unstripped tap wire completely and check
3. Hold tool perpendicular to the wires and make the
4. Close hinged top cover until latched.
Regulatory Agencies
UL Listed - Tested per UL Standard 486C
UL file No. E23438
CSA certified - CSA Std. C22.2 No. 0. 188-MI983
CSA File No. LR15503, LR32411
(Voltage rated at 600 volts maximum, building wire:
1000 volts maximum, signs, fixtures and luminaires.
Operating Temperature: 105˚C.)
WARNING
Turn power off before installing or removing terminal. All electrical
work should be done according to appropriate electrical codes.
it’s position in the inspection port.
connection by driving the u-contact down flush
with the top of the plastic insulator.
Crimping Tool No. E-9BM

Related parts for 567 (BOXED)

567 (BOXED) Summary of contents

Page 1

... Color - brown Weight .0067 lb. (3.0 gm) ™ 567 Recommended Installation Tools 9” Linemans Pliers 3M Crimping Tool No. E-9BM ™ Installation Instructions WARNING Turn power off before installing or removing terminal. All electrical work should be done according to appropriate electrical codes. 1. Place unstripped run wire inside run channel. ...

Page 2

... FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential regardless of the legal theory asserted ...