2002-1611 WAGO, 2002-1611 Datasheet - Page 2

TERMINAL BLOCK, FUSED, 22-12AWG, 5X20MM

2002-1611

Manufacturer Part Number
2002-1611
Description
TERMINAL BLOCK, FUSED, 22-12AWG, 5X20MM
Manufacturer
WAGO
Series
TOPJOBr
Datasheet

Specifications of 2002-1611

Connector Type
Fused Terminal Block
Connector Mounting
DIN Rail
No. Of Contacts
2
Pitch Spacing
6.2mm
Wire Size (awg)
22-12
Fuse Size Held
5 X 20mm
No. Of Positions
2
Color
Gray
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
34
1
?
Fuse Disconnect Terminal Blocks with Pivotable Fuse Holder,
2.5 (4) mm
Description
Fuse disconnect terminal block
with pivotable fuse holder,
for DIN 35 rail,
for miniature metric fuses
Article-specific accessories
Accessories
(see also Full Line Catalog W4, Volume 1, Section 15)
Nominal voltage and current are given
by the LED or fuse
Leakage current in case of blown fuse:
LED 6 mA
800 V = rated voltage
8 kV = rated surge voltage
3 = pollution degree
2
/AWG 12, for Miniature Metric Fuses 5 x 20 mm, Series 2002
Appropriate marker systems:
5 x 20 mm
5 x 20 mm
5 x 20 mm
0.25
250 V/6 kV/3
6.3 A
Terminal block width 6.2 mm / 0.244 in
L 10 — 12 mm / 0.43 in
2-conductor fuse terminal block with end plate,
without blown fuse indication
gray
End plate for fuse terminal blocks, 2 mm/0.079 in thick
Insulation stop, 5 pcs/strip
Protective warning marker, with high voltage symbol, black,
Push-in type jumper bars, light gray, insulated, I
Push-in type jumper bars, light gray, insulated, I
Test plug, with cable 500 mm/1’7.7’’, Ø 2 mm/0.079 in Ø
WMB/Marker Strips/WMB Inline
2.
5 (4) mm
<_______ 66,5 mm /2.62 in _______>
2002-1611
Item no.
gray
orange 2002-992
light gray 2002-171 0.25-0.5 mm
dark gray 2002-172 0.75-1 mm
must be singularized
for 5 terminal blocks
yellow
must be singularized
2-way
3-way
4-way
5-way
10-way 2004-410 100 (4 x 25)
1 - 3
1 - 4
1 - 5
1 - 10
red
:
2
:
2002-991
2002-115 100 (4 x 25)
2004-402 200 (8 x 25)
2004-403 200 (8 x 25)
2004-404 200 (8 x 25)
2004-405 100 (4 x 25)
2004-433 200 (8 x 25)
2004-434 200 (8 x 25)
2004-435 100 (4 x 25)
2004-440 100 (4 x 25)
210-136
:
:
AWG 22 — 12
100 (4x25)
100 (4x25)
50 (5 x 10)
50
Pack. unit
200 strips
(see Full Line Catalog W4, Volume 1, Section 14)
N
N
25 A
25 A
2
2
0.25
250 V/6 kV/3
6.3 A
Terminal block width 6.2 mm / 0.244 in
L 10 — 12 mm / 0.43 in
2-conductor fuse terminal blocks with end plate,
with blown fuse indication by LED
gray 12 — 30 V ≃
gray 30 — 65 V ≃
gray 110 — 250 V ≃
End plate for fuse terminal blocks, 2 mm/0.079 in thick
Insulation stop, 5 pcs/strip
Protective warning marker, with high voltage symbol, black,
Push-in type jumper bars, light gray, insulated, I
Push-in type jumper bars, light gray, insulated, I
Test plug, with cable 500 mm/1’7.7’’, Ø 2 mm/0.079 in Ø
2.
<_______ 66,5 mm /2.62 in _______>
5 (4) mm
2002-1611/1000-836
2002-1611/1000-541
2002-1611/1000-542
Item no.
gray
orange 2002-992
light gray 2002-171 0.25-0.5 mm
dark gray 2002-172 0.75-1 mm
must be singularized
for 5 terminal blocks
yellow
must be singularized
2-way
3-way
4-way
5-way
10-way 2004-410 100 (4 x 25)
1 - 3
1 - 4
1 - 5
1 - 10
red
:
2
:
2002-991
2002-115 100 (4 x 25)
2004-402 200 (8 x 25)
2004-403 200 (8 x 25)
2004-404 200 (8 x 25)
2004-405 100 (4 x 25)
2004-433 200 (8 x 25)
2004-434 200 (8 x 25)
2004-435 100 (4 x 25)
2004-440 100 (4 x 25)
210-136
:
:
AWG 22 — 12
50
50
50
100 (4x25)
100 (4x25)
50 (5 x 10)
Pack. unit
200 strips
N
N
25 A
25 A
2
2