31-71016-RFX AMPHENOL RF, 31-71016-RFX Datasheet

no-image

31-71016-RFX

Manufacturer Part Number
31-71016-RFX
Description
RF/COAXIAL, BNC BHD JACK STR 75OHM CRIMP
Manufacturer
AMPHENOL RF
Type
Cable Jackr
Datasheet

Specifications of 31-71016-RFX

Body Style
Straight Bulkhead Jack
Coaxial Termination
Crimp
Rg Cable Type
RG-179, 187, Belden 9221
Contact Material
Beryllium Copper
Connector Type
BNC Coaxial
Impedance
75ohm
Angle
Straight
Application
Commercial
Cable Type
RG/U 179B,187A M17/94,179
Contact Plating
Gold
Finish, Housing
Nickel
Gender
Jack
Material, Contact
Brass (Male), Beryllium Copper⁄Phosphor Bronze (Female)
Material, Dielectric
TFE/Styrene
Material, Housing
Brass
Mating Type
Bayonet
Mounting Type
Bulkhead
Primary Type
BNC
Temperature, Operating
-65 to +165 °C
Termination
Crimp
Voltage, Rating
500 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Assembly Instructions-C7R
BNC
Amphenol Corporation Tel: 800-627-7100
2-PIECE CRIMP PLUGS
Step 1
Step 2
Step 3
31-5556-RFX
31-5557-RFX
31-5560-RFX
Amphenol
Number
BNC Plug
BNC Plug
BNC Plug
Connector
Type
a
b
59, 62
58
Plenum 59, 62
c
RG-/U
Cable
outer ferrule
Outer Ferrule
.324(8.2)
.324(8.2)
.324(8.2)
Cavity for
279
Hex Crimp Data
Tool 227-944*
227-1221-32
227-1221-32
227-1221-32
Die Set for
Step 1 Strip cable jacket, braid, and dielectric to dimensions
Step 2 Flare slightly end of cable braid as shown to facilitate
Step 3 Install cable assembly into body assembly so that inner
plug body assembly
in table above. All cuts are to be sharp and square.
Important: Do not nick braid, dielectric, and center
conductor. Slide outer ferrule onto cable as shown.
insertion of inner ferrule of connector. Important: Do not
comb out braid.
ferrule portion slides under braid. Slide outer ferrule over
braid and up against connector body. Crimp outer ferrule
using Die Set Cavity specified in table above.
Tool Number
CTL Series
CTL-2
CTL-2
CTL-2
.437(11.1)
.437(11.1)
.437(11.1)
a
Stripping Dimensions, inches (mm)
.312(7.9)
.312(7.9)
.312(7.9)
Amphenol
b
www.amphenolrf.com
.248(6.3)
.248(6.3)
.248(6.3)
c
.125(3.2)
.125(3.2)
.125(3.2)
d
®

Related parts for 31-71016-RFX

31-71016-RFX Summary of contents

Page 1

... Slide outer ferrule over braid and up against connector body. Crimp outer ferrule using Die Set Cavity specified in table above. 279 Amphenol ® Stripping Dimensions, inches (mm .437(11.1) .312(7.9) .248(6.3) .125(3.2) .437(11.1) .312(7.9) .248(6.3) .125(3.2) .437(11.1) .312(7.9) .248(6.3) .125(3.2) www.amphenolrf.com ...

Page 2

... Not supplied on all items Step 1 a Step 2 Step 3 Step 4 Step 5 For angle plugs only: (except 31-204) Solder center conductor to preassembled contact. Assemble cap and lightly punch center of cap for retention in body, or solder in place. Amphenol Corporation Tel: 800-627-7100 clamp bushing‡ female contact jack body ‡ ...

Page 3

... Slide outer ferrule onto cable as shown. For RG-174, 179, 187, 188, 316/U cables only, slit jacket back .100"(2.5mm) as shown. Before attaching center contact, slide metal spacer/TFE sleeve (not shown) over cable dielectric and under braid. The center contact should butt against the dielectric and TFE sleeve ...

Page 4

... Step For RG-174, 179, 187, 188, 316/U cables only, slit jacket back .100"(2.5mm) as shown. Before attaching center contact, slide metal spacer/TFE sleeve (not shown) over cable dielectric and under braid. The center contact should butt against the dielectric and TFE sleeve. ...

Page 5

... Cable Number Type RG-/U 31-351 BNC Plug 58, 141 31-359 BNC Plug 59, 62, 140 31-371 BNC Plug 174, 179, 187, 188, 316 boot Step 1 outer ferrule Step 2 Step 3 outer ferrule must Step 4 clamp nut assy as shown Step 5 note: center conductor must be visible thru contact solder ...

Page 6

... BNC Plug 59 31-5137 BNC Plug 58 31-5137-RFX BNC Plug 58 Step 1 Strip cable as shown. Take care not to nick center conductor or outer braid. Step 2 Twist outer braid in a clockwise direction so that at least min. of cable 1/32" of cable dielectric is bared, and braid is left flat. (Stray dielectric or loose braid can cause shorts ...

Page 7

... Slide clamp nut over cable. Strip cable to dimension shown. Cut braid and dielectric square. Do not nick center conductor. Step 1B For 31-4541-RFX.. Same as step 1A except use Step 1B strip dimensions, and then slit jacket back .125"(3.2 mm) in four places 90° apart as shown in illustration. ...

Page 8

... Connector Cable Number Type RG-/U 31-4700 BNC Plug 58, 141 31-4702 BNC Plug 59 .250(6.4) .156(4.0) Step 1 Slide ferrule over cable end, slotted end first. Strip cable to dimensions shown. Do not nick center conductor. Flare braid slightly as shown. Step 2 Tin exposed center conductor. Solder center contact on center conductor ...

Page 9

... Belden 8281, 9231 a Step 1 For RG-174, 179, 187, 188, 316/U cables only, slit jacket back .100"(2.5mm) as shown. Before attaching center contact, slide TFE sleeve (not shown) over cable dielectric and under braid. The center contact should butt against the dielectric and TFE sleeve. ...

Page 10

... BNC Plug 179, 187 31-71013-1000 75 BNC Plug Dbl. Br. RG-179 31-71014-RFX 75 BNC Jack 179, 187 31-71016 75 BNC Bulkh. Jack 179, 187 31-71016-RFX 75 BNC Bulkh. Jack 179, 187 31-71032 75 BNC Plug B8281, 88281 31-71033 75 BNC Plug B8218 31-71034 75 BNC Plug Belden 89292 ...