PROTEXT-DIN RF Solutions, PROTEXT-DIN Datasheet - Page 8

no-image

PROTEXT-DIN

Manufacturer Part Number
PROTEXT-DIN
Description
MOD, DIN, GSM REMOTE CONTROL SYSTEM
Manufacturer
RF Solutions
Datasheet

Specifications of PROTEXT-DIN

Svhc
No SVHC (15-Dec-2010)
Accessory Type
GSM Telemetry System
Power Supply Output Voltage @ Current
240VAC
Supply Voltage
24V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
11.
PLEASE NOTE: ~ Denotes a ‘space’ in the format of a message
DSPROTEXT-3 Mar 09
Retrieve unit settings
inputs and outputs
deactivate outputs
Retrieve status of
Activate and
(SETTINGS)
Command
(STATUS)
Control Commands
(OUT)
This command is used to turn a relay output on or off.
This command requests that the status of the inputs
and outputs be returned to this caller.
This command requests that the settings of the unit
be returned to the caller.
PROTEXT - GSM R
Description
©2009 REG No 277 4001, ENGLAND.
EMOTE
<UNIT PW>~OUTn~x
<UNIT PW>~STATUS
n=Relay number = 1 to 8
x=Relay Status = ON, OFF
<UNIT PW>~SETTINGS
Command Syntax
C
ONTROL
Command:
Password38~OUT1~ON
Response:
Identity7~OUT1~ON~OK
Command:
Password38~STATUS
Response:
Identity7~IN1ON~IN2OFF~OUT1ON~OUT2ON
Command:
Password38~SETTINGS
Response:
Identity7~SETTINGS~ODEL1~2~ODEL2~0
Example
Page 8