5 Power Down and Power up Sequence
To protect OLED panel and extend the panel life time, the driver IC power up/down routine
should include a delay period between high voltage and low voltage power sources during
turn on/off. Such that the panel has enough time to charge up or discharge before/after
operation.
Power up Sequence:
1. Power up V
2. Send Display off command
3. Driver IC Initial Setting
4. Clear Screen
5. Power up V
6. Delay 100ms
(when V
7. Send Display on command
Power down Sequence:
1. Send Display off command
2. Power down V
3. Delay 100ms
(when V
panel is completely
discharges)
4. Power down V
Product No.
Copyright ©2008 DENSITRON TECHNOLOGIES plc. All rights reserved. – Proprietary Data
DD
DDH
is stable)
is reach 0 and
DD
DDH
DDH
DD
DD-128128FC-5B
REV. B