CMD-12DP512 AXIOM, CMD-12DP512 Datasheet - Page 18

no-image

CMD-12DP512

Manufacturer Part Number
CMD-12DP512
Description
Single Board Computer
Manufacturer
AXIOM
Datasheet

Specifications of CMD-12DP512

Silicon Manufacturer
Freescale
Core Architecture
HCS12
Core Sub-architecture
S12D
Features
Onboard Back Ground Debug, Breadboard And Prototype Area
Kit Contents
Board
Silicon Family Name
S12D
Silicon Core Number
MC9S12DP512
C M D - 1 2 D P 5 1 2
TEST POINTS
The following test points are provided on the development board:
EXTAL : HCS12 oscillator or external clock input pin.
XTAL : HCS12 oscillator output pin.
XFC : HCS12 PLL reference voltage and filter.
VDDPLL : HCS12 PLL voltage source test point.
TROUBLESHOOTING
The CMD-12DP512 board is fully tested and operational before shipping. If it fails to function
properly, inspect the board for obvious physical damage first. Review the GETTING STARTED
section of this manual and verify the option settings and connections. See the Tips and
Suggestions sections following for more information.
1. USB connection suspect: Follow these steps to verify USB operation –
2. NO PWR indicator: Verify the power source and POWER option is installed. +8 volts DC
3. If no voltage is found, verify the wall plug connections to AC wall plug outlet and the power
4. Verify the logic power source. Measure +5 volts between the GND and +5V connections
5. Disconnect all external connections from the CMD-12DP512 board except for USB to the
6. Make sure that the RESET Indicator is not on all the time.
or higher voltage may be measured between the GND and +VIN connections on the TB1
power connector with the standard power supply provided and plugged into the J1
connector.
connector. If applying a power strip make sure it is turned ON.
on the TB1 power connector. If the +VIN supply is good and this supply is not +5V,
immediately disconnect power from the board. Contact
instructions and provide board name and problem.
PC and the wall plug.
a) Disconnect the CMD-12DP512 board USB connector, power connection, and close
b) Connect the CMD-12DP512 USB port to the host PC and verify the USB connection
c) Connect power to the CMD-12DP512 board and verify PWR Indicator is ON.
d) Launch the AxIDE4 software and select the Tester window. Verify connection by
the AxIDE4 software.
is recognized by the PC. Board STATUS indicator should be ON.
performing Tester commands.
R E V
B .
18
support@axman.com
0 8 / 2 3 / 0 7
by email for

Related parts for CMD-12DP512