J6301NR VERMASON, J6301NR Datasheet

no-image

J6301NR

Manufacturer Part Number
J6301NR
Description
PLUG, EARTH BONDING POINT
Manufacturer
VERMASON
Datasheet

Specifications of J6301NR

End To Ground Resistance
1Mohm
No. Of Studs
1
Approval Bodies
EN 100015-1
Svhc
No SVHC (18-Jun-2010)
Colour
Yellow
No. Of Stud Size 1
1
Standard
EN100015-1
Stud Size 1
10mm
Terminal Type
St
Lead Free Status / RoHS Status
na
© 2007 VERMASON LTD.
Item
231180 UK Plug with 1 x 4mm Stud, 2 x 10mm Studs
231200 UK Plug with 3 x 10mm Studs
231230 UK Plug with 2 x 4mm Plug Sockets, 1 x 10mm Stud
231195 UK Plug with 1 x 10mm Stud, No Resistor
231185 UK Plug with 1 x 10mm Stud
231225 UK Plug with 1 x 2BA Binding Post
Property
Colour
Size of plug casing
Weight
Connector to earth pin resistance
Connector to connector resistance
Description
Value
Yellow
51 x 49 x 31mm
36g
0.95 - 1.05MΩ
approx 2MΩ
A. The Vermason Earth Bonding Point (EBP) plug is designed to provide a safe effective and
B. The normal earth contact is linked via individual 1 MΩ resistor rated at 1/2W. In the event of a
C. If overstressed the resistor will open the circuit.
D. It is virtually impossible to misuse the plug, which is permanently sealed. The resistance
E. Check that the connectors on the plug face correspond with the terminations on the wrist
F. The plug is ONLY to be used for ESD control purposes.
G. ONLY use ground cords with compatible connections to those on plug. Vermason supply EBP
H. NOT to be used for earthing electrical appliances
I.
J. Each termination is connected to its own 1MΩ resistor. The resistance between two
K. To avoid the need for unduly long ground cords and to simplify the daily visual check, that all
L. The EBP plug may also be used in conjunction with a Vermason EBP box or bar installed at
M. EBP plugs are packed and labelled individually in an antistatic polyethylene bag.
easy to use earthing point in an ESD protected area (EPA). The plug fits into the mains
supply socket, making a connection with the earth conductor only. In place of the live and
neutral pins are moulded insulating plastic pins to allow positive location in the socket.
Connectors on the front of the plug are available for connection via ground cords to the
various elements of the EPA. Thus each element is held at a common potential.
workstation element becoming live the resistor will limit the fault current to less than 0.3mA at
240V, and is capable of withstanding 500VDC for 6 minutes.
between the terminations and the pin of each plug is tested after manufacture.
strap and ground cords: several variations of the plug are available. Insert the EBP plug into a
mains supply socket and push it fully home. The plug functions safely whether the socket is
switched off or on. Connect the elements of the EPA such as bench and floor mats to the EBP
plug face using ground cords.
plugs with terminations for all standard ground cords.
DO NOT open or try to repair. Test the plug by measuring the resistance from each
termination to the Earth pin. Resistance should be between 0.9 and 1.1MΩ.
terminations should be approximately 2MΩ
connections are sound and in place, an EBP plug should not be shared by more than two
work stations.
the front of a bench for easier connecting of wrist straps for example.
UK Earth Bonding Plugs
E-MAIL:Service@Vermason.co.uk, INTERNET: Vermason.co.uk
PHONE: +44 (0) 1462-672005, FAX: +44 (0) 1462-670440
1 AVENUE ONE, LETCHWORTH, HERTS, SG6 2HB UK
VERMASON LTD.
Drawing Number
231180
Made in Britain
May 2007
DATE: