MCTA060/12 MULTICOMP, MCTA060/12 Datasheet

TOROIDAL TRANSFORMER

MCTA060/12

Manufacturer Part Number
MCTA060/12
Description
TOROIDAL TRANSFORMER
Manufacturer
MULTICOMP
Datasheet

Specifications of MCTA060/12

Secondary Voltages
12
Transformer Mounting
Chassis
Weight
0.75kg
Transformer Type
Toroidal
Output Current, Secondary Series
2.5A
Supply Voltage
115V
Output Voltage
12V
Output Current
2.5A
Power Rating
60VA
Rohs Compliant
Yes
Mounting Type
Donut
Output Current, Secondary Parallel
5A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Toroid International Ltd
Princes Court, Edward House
Beam Heath Way
Nantwich
Cheshire CW5 6PQ
Tel:
Fax:
Mobile: +44 (0) 831 345413
Construction Details for Toroidal Transformer TA060/12
The transformer is designed and constructed to meet requirements in UL1411, EN60742 (old BS3535)
and CSA 22.2 No.1-94 and construction requirements in our UL file E115159.
The transformer is constructed in the following order:
Electrical performance as in enclosed Transformer Specification.
Detailed description of design and materials:
1.
2.
3.
4.
5.
6.
7.
Core with core protection.
Primary winding
Primary to Secondary insulation.
Secondary winding
Final Insulation
Core from 0.3 mm thick silicon steel Grade M5 Edges are ground smooth before final annealing.
Core Protection, from 4 layers (2 layers with 50% overlap) of 0.05 mm thick polyester film (approved
by CSA for temperature class B, 130 deg C).
Main supplier: Dupont, UL file E93687(R).
Primary Winding Wire, Copper wire, polyesterimid enameled Grade 2 (according to IEC 317-8) and
temperature class 180 degrees C.
Primary Lead outs, from type UL1015, 22 AWG (UL approved under Guide AVLV2 for 300V and
105 degrees C). VW-1.
Main supplier: Sumitomo Electric, UL file E41105
Primary to Secondary Insulation from 6 layers (3 layers with 50% overlap) of 0.05 mm thick
polyester film. Material as in 2.
Secondary Winding Wire, Copper wire, polyesterimid enameled Grade 2 (according to IEC 317-8)
and temperature class 180 degrees C.
Secondary Lead outs, from type UL1015, 22 AWG (UL approved under Guide AVLV2 for 300V and
125 degrees C). VW-1.
Main supplier: Sumitomo Electric, UL file E41105
+44 (0) 1270 611368
+44 (0) 1270 611369
TA060/12 Specification
Toroid
1

Related parts for MCTA060/12

MCTA060/12 Summary of contents

Page 1

Toroid International Ltd Princes Court, Edward House Beam Heath Way Nantwich Cheshire CW5 6PQ Tel: +44 (0) 1270 611368 Fax: +44 (0) 1270 611369 Mobile: +44 (0) 831 345413 Construction Details for Toroidal Transformer TA060/12 The transformer is designed and ...

Page 2

Contd. 8. Final Insulation, from 2 layers (1 layers with 50% overlap) of 0.05 mm thick polyester film. Material Transformer mounting, Supplied with 1x 70mm metal mounting disks (6.5mm hole) and 2x 70mm foam rubber mounting ...

Page 3

TOROID International Ltd ┌──────────────────────────────────────────────────────────────────┐ │ Transformer TA060/12 (TI-69102) Issue 2 ├──────────────────────────────────────────────────────────────────┤ │ PRIMARY │ │ Bwn 150mm 22AWG • │ 115 V o─────────────────▄ │ │ │ Vio 150mm 22AWG █ │ o─────────────────▀ │ │ │ Gry 150mm 22AWG ...

Related keywords