37022 Simpson, 37022 Datasheet - Page 18

Current Transformer

37022

Manufacturer Part Number
37022
Description
Current Transformer
Manufacturer
Simpson
Type
Inductiver
Datasheets

Specifications of 37022

Input Current
200A
Frequency Range
50Hz To 400Hz
Transformer Mounting
Chassis
Secondary Current Nom
5A
Winding Configuration
200
Power Rating
5VA
Mounting Type
Foot Mounted
Accuracy
± 1 %
Current, Ratio
200:5
Diameter, Inside
3.78 in.
Diameter, Outside
3.53 in.
Frequency Response
50 to 400 Hz
Function
Current
Height
4.22 in.
Length
3.53 in.
Material, Stud
Brass
Primary Type
Current
Range, Measurement
200 A
Technology
Inductive
Thickness
2.15 in.
Transformer Type
Current
Width
0.071 in.
Dimensions
89.66 mm L x 96.01 mm H
Number Of Outputs
1
Primary Voltage Rating
200 V
Termination Style
Screw Terminals
Turns Ratio
500
Rohs Compliant
No
Current Ratio
200
Leaded Process Compatible
No
Output Current
5A
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
To monitor AC current
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
14
A
Installation and Panel Cutout - H335, H340, H345
Mounting Requirements
The Hawk 3 Advanced Digital Controller 1/8 DIN meters require a
panel cutout of 1.77” (45mm) high and 3.62” (92 mm wide). To
install the Hawk 3 meter into the panel cutout, remove the clips from
the side of the meter. Slide the meter through the panel cutout, then
slide the mounting clips back on the meter. Press evenly to ensure
a proper fit. Tighten screws.
Inputs
DC Voltage
AC Voltage
Range Resolution Resolution
200mV 10µV
2 V
20 V
200 V
600 V
Range Resolution Resolution
200mV 10µV
2 V
20 V
200 V 10 mV
600 V .1 V
.1mV
1mV
.1mV
1mV
10 mV
.1 V
4.5
4.5
.1 mV
1 mV
10 mV
1V
.1 V
.1 mV
1 mV
10 mV
.1 V
1V
3.5
3.5
Impedance
Impedance
200K
200K
2 M
2 M
2 M
1 M
1 M
2 M
2 M
2 M
Input
Input
3.59”
3.93”
10DCV
100DCV
300DCV
300DCV
1K DCV
Overload
10DCV
100DCV
100DCV
300DCV
1K DCV
Overload
DC Current
Range Resolution Resolution
200µA
2 mA
20 mA 1µA
200 mA 10 µV
2 A
5 A
2.04”
.1 mA
.1µA
.1 mA
4.5
.52”
10 nA
.1 mA
1 mA
10 mA
.1 mA
1 mA
1 mA
3.5
1.77”
Impedance
3.24”
1K
100
10
1
.013
.013
Input
3.62”
Engineering Label Placement
To replace the engineering unit label, place the tip of a ballpoint pen
into the small hole at the base of the engineering label in the bezel.
Slide the label up until it pops out. Grasp and remove. Slide the
new label half the distance in, then use the ballpoint pen to slide it
into place.
11mA DC
35mA DC
111mA DC
353 mA DC
7A DC
7A DC
Overload
1.75”
AC Current
Range Resolution Resolution
200µA 10 nA
2 mA
20 mA 1µA
200 mA 10 µV
2 A
5 A
Resistance
Range Resolution Resolution
200m
2
20
200
.1µA
.1 mA
.1 mA
10m
1
10
.1
4.5
4.5
.1 mA
1 mA
10 mA
.1 mA
1 mA
1 mA
.1
1
10
.1
3.5
3.5
Impedance
Impedance
1K
100
10
1
.013
.013
1.2K
12K
121
1.2M
Input
Input
11mA AC
35mA AC
111mA AC
353mA AC
7A AC
7A AC
Overload
Overload
5DCV
5DCV
5DCV
5DCV

Related parts for 37022