01306 Simpson, 01306 Datasheet - Page 11

Current Transformer

01306

Manufacturer Part Number
01306
Description
Current Transformer
Manufacturer
Simpson
Type
Inductiver
Datasheets

Specifications of 01306

Input Current
75A
Turns Ratio
15
Transformer Mounting
Chassis
Secondary Current Nom
5A
Power Rating
2VA
Peak Reflow Compatible (260 C)
No
Output Current
5A
Mounting Type
Donut
Transformer Type
Current
Accuracy
2 %
Current, Primary
75 A
Current, Ratio
75:5
Current, Secondary
5 A
Diameter, Inside
1.56 in.
Diameter, Outside
3.56 in.
Frequency Response
50 to 400 Hz
Function
Current
Material, Stud
Brass
Primary Type
Current
Range, Measurement
75 A
Standards
UL and CSA Approved
Technology
Inductive
Thickness
1.1 in.
Dimensions
27.94 mm W
Number Of Outputs
1
Primary Voltage Rating
75 V
Secondary Voltage Rating
5 V
Termination Style
Round Crimp Terminals
Current Ratio
75
Leaded Process Compatible
No
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
The primary wire passing through the core, or by wrapping the secondary wires leading to the meter
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
• 1/8 DIN Indicator
• 3-1/2 or 4-1/2 digit bright red LED display
• Front panel pops off for easy decimal
• Only 3.12” (79mm) required behind panel
• Optional excitation output
• NEMA 4X enclosure optional
• Din Rail Adapter available
Mounting Requirements
The Falcon series 1/8 DIN indicators require a panel cutout of
1.77" (45mm) high by 3.62" (92mm) wide. To install the Falcon
into a panel cutout, remove the clips from the side of the meter.
Slide the meter through your panel cutout, then slide the mount-
ing clips back on the meter. Press evenly to ensure a proper fit.
Tighten screws.
point setting and display scaling
(page C1)
Dimensions
Specifications
DISPLAY
Type
Height
Decimal Point
Overrange indication
Polarity
POWER REQUIREMENTS
AC Voltages
DC Voltages
Power Consumption
ACCURACY @25°C
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
Warm-up Time
Response Time
NOISE REJECTION
NMRR
CMRR
A TO D CONVERSION
Technique
Rate
MECHANICAL
Bezel
Depth
Panel Cutout
Case Material
Weight
F45 DC Process/Voltage
F35 DC Process/Voltage
F45 DC Current
F35 DC Current
F45 AC Voltage/Current
F35 AC Voltage/Current
4.04”
3.59”
3.75
1.88
7-segment, red LED
0.56" (14.2mm)
3 or 4 position user-programmable,
internally or on the terminal block
most significant digit = "1"; other digits
blank
Automatic, with "-" indication,
"+" indication implied
120 or 220VAC, ±10% 50/60Hz
9-32DCV, ±1%
F35: 3VA, F45: 2VA
±0.02% of reading ± 1 count
750 ± 2 count
±0.1% of reading ± 1 count
750 ± 2 count
±0.05% of reading ±1 count
2A ± 5 counts
±0.1% of reading ± 1 count
2A ± 5 counts (45Hz-1KHz)
±0.5% of reading ± 35 counts (45Hz-1KHz)
±1% of reading ± 5 counts (45Hz-1KHz)
0 to 55°C
-10 to 60°C
0 to 85% non-condensing
(±0.1% of input ± 0.5 count)/°C
Less than 15 minutes
Less than 3 seconds
50dB, 50/60Hz
(w/1K unbalanced @ 60Hz) 90dB min.
Dual slope integration
3 samples per second, nominal
3.75" x 1.88" x .51"
2.94"
3.62" X 1.77"
94V-1, UL rated Noryl®
9.0oz (255.1g)
.51
2.94
5A ± 5 counts
92 mm
1.75
more >>
2.26

Related parts for 01306