ETU17 TIMEGUARD, ETU17 Datasheet
![TIME SWITCH, PLUG-IN, 7DAY](/photos/23/84/238468/42267144_sml.jpg)
ETU17
Specifications of ETU17
ETU17 Summary of contents
Page 1
... Timeguard ETU17 7 Day Digital Plug-In Time Controller Farnell SKU – 678-284 The Timeguard ETU17 has all the features and benefits of the Timeguard ETU11 plus individual day, every day, every weekday or weekend programme selections over a 7 day period. Six programmes are available and if selected to operate over all 7 days & ...
Page 2
... COMPACT 7 DAY TIMESWITCH Cat No. ETU17 ...
Page 3
... Introduction The ETU17 is a compact seven day timeswitch which has six programmes, each of which can be dedicated to 7 day, 5 day, 2 day or individual day operation. It has a random switching capability useful for security applications also able to switch ...
Page 4
... Battery This product has a factory fitted rechargeable battery. If the ETU17 is left out of a live socket for more than 1 month the display may go blank. In this case plug into a live socket, wait four hours, and apply reset - see section 1 before programming. Programming Overview ...
Page 5
... ON programme time Set Programme ON/OFF Times (after clock setting) It must be remembered that the ETU17 has a total of six programmes The user is now able to set the day(s) that the first programme will operate on. The alternatives are: ...
Page 6
... Release the buttons and the display will fill with its complete range of characters and then clear to show clock and day 1 symbol flashing. This procedure is essential with a new ETU17 and is recommended if major reprogramming is required subsequently. You are now in the clock setting mode at the ...
Page 7
... IMPORTANT After setting a clock time which falls within a programmed ON period, the unit will not switch ON. Press the <Change> button to switch the ETU17 ON (the ON will flash to indicate an override situation). After this the unit will operate normally to the programmes set. 4. Programme Review To fast review the set programmes or for quick exit to normal operating mode - press and hold down the < ...
Page 8
Having reached the clock time and day or programme time and day(s) requiring change, press the <Change> button briefly to initiate programme mode and then follow sections 2 and 3 as required. Having completed the change press and hold down ...
Page 9
... Random Operation By pressing the <Change> for around three seconds whilst in normal operating mode a small R appears on the display. The ETU17 will now switch ON and OFF in a random fashion during programmed ON periods. Both the ON and the OFF periods will vary in a random way between 10 and 31 minutes. Normal switching can be restored by pressing the < ...
Page 10
Year Guarantee In the unlikely event of this product becoming faulty, due to defective material or manufacture, within 3 years of the date of purchase, please return it to your supplier in the first year with proof of ...
Page 11
... HELPLINE 020-8450-0515 For a product brochure please contact: Timeguard Ltd. Victory Park, 400 Edgware Road, London NW2 6ND 020-8452-1112 or email csc@timeguard.com Designed and manufactured in the U.K. 67-058-04 (issue 3) ...