TGV101 TIMEGUARD, TGV101 Datasheet

no-image

TGV101

Manufacturer Part Number
TGV101
Description
SOCKET, SWITCHED, SINGLE, IP66
Manufacturer
TIMEGUARD
Datasheet

Specifications of TGV101

Approval Bodies
BS1363
Colour
Dark Grey
Current Rating
13A
External Depth
75mm
External Length / Height
132mm
External Width
117mm
Ip/nema Rating
IP66
No. Of Gangs
1
Operating Temperature
RoHS Compliant
Svhc
No SVHC (15-Dec-2010)
Rohs Compliant
Yes
IP66 Products covered by
these instructions
TGVL01
TGVL02
TGVL03
TGVL05
TGV101
TGV201
TGV104
TGV204
TGV205
TGV203
TGV103
Installation and Operating
Weathersafe Vision
One gang two way switch 10AX
Two gang two way switch 10AX
One gang bell push
One gang double pole switch 20A
One gang socket switched 13A
Two gang socket switched 13A
One gang RCD spur
Two gang RCD protected socket
13A (passive/latching)
Two gang RCD protected socket
13A (active/non-latching)
Combined timer and socket
One gang switched fused spur 13A
Instructions
General
Please note that all instructions are to be left with the
customer after installation.
The Weathersafe Vision range is manufactured from
tough, durable thermoplastic, and is intended for use in
an outdoor environment, or one in which the protection
provided by the Weathersafe Vision range is required.
All the products are rated IP66, for protection against
water and dust. All Weathersafe Vision products need to
be fi tted with waterproof cable and conduit entries to
maintain their IP rating once installed.
The weather plus range complies with the following
standards.
• IP66 rating: BS EN 60529
• Socket outlets: BS 1363
• RCD units: BS 7288
• Fused connection units: BS 1363
• Switches: BS EN 60669
• All products in the range comply with the low
Voltage: 230V AC 50Hz
Operating temperature range: -5° to 55°C
Installation instructions
• These products should be installed by a competent
• Disconnect the mains electricity supply
• The Weathersafe Vision range is designed to be
• The rear box shall be mounted on the wall using no.8
• If the mounting surface is uneven use a sheet of
Fig. 1
Rear Box (double)
4 x fi xing holes for
no. 8 woodscrews
Drain feature,
use only lower if
required
Front cover
fi xing holes
voltage directive LV 72/23/EEC and where
relevant the EMC directive 89/336/EEC
person (e.g. qualifi ed electrician) in accordance with
these instructions and in compliance with the
appropriate clauses of the current edition if the IEE
wiring and building regulations. Sockets should be
connected via a suitable RCD device.
before installing.
mounted on a vertical fl at surface, with socket outlets
not more than 1 metre above the ground.
wood screws and wall plugs if necessary (see fi g. 1).
marine ply as a base plate then fi t the rear box to it.
If conduit is to be used then please follow the
instructions below:
• The drain feature must be drilled out using
• If bottom entry conduit is used, there must be
• The relevant cable entry knockout should
• If two cable entry positions are used with
• Ensure that the gasket is correctly fi tted,
Operating Instructions
Fig. 2
Single and double boxes – side view of bottom.
• The lid may be opened by pressing in the tab(s)
• Plugs may be inserted into the sockets and the
• The lid should then be closed to maintain the
a 5mm drill if top or side entry conduit is used.
Opening this drain hole will reduce the IP rating
of the product. Remember – open out the lower
drain feature only and only if required by
conduit entry being used.
adequate drainage from the lowest point of
the conduit.
be carefully removed by scoring the groove
around the knockout with a sharp knife and
then tapping it out with a small hammer.
A waterproof cable or conduit entry must
then be fi tted in its place.
metal conduit, then earth continuity between
the conduits must be maintained.
and tighten the four screws (supplied) to fi x
the front cover in place (see fi g. 1). Do not
overtighten. Use of an electric screwdriver
is not recommended.
on the front to release the snaps and then lifting
the lid (see fi g.2).
socket switches turned on.
IP rating taking care to ensure that the cables
are aligned with the centre of the cable seals
(see fi g. 3). Finally engage the snaps (see fi g. 2)
by pulling out the tab(s) while maintaining
pressure to close the lid.
Push here and lift up
Snaps
Snaps
Fig. 3
Rear Box (double with 2 gang RCD sockets)
Cleaning
• Care should be taken when cleaning
• Inside the lid should only be wiped with a
• The outside can be cleaned with
• Solvent based cleaners should not be used.
• Advice should be sought before installing this
Weathersafe Vision Products with RCD’s
(TGV104, TGV204, TGV205)
Always test the RCD before use.
To test: Ensure supply is connected
RESET – press the grey (blue for TGV205) button
marked Reset (R), the status indicator should show red.
TEST – press the red button marked Test (T),
status indicator should show black. This indicates
that the RCD has been tripped and power has been
disconnected from the outlet.
RESET – press the grey (blue for TGV205) button
marked Reset (R) again, the status indicator
should show red.
If all the above operations work satisfactorily, the RCD
is safe for use.
If the procedure is not completed satisfactorily do not
use the RCD and seek professional advice.
In applications such as hand driers it may not be
practical to expect each user to test before use. In this
case we suggest an appropriate person applies the test
routine twice a day.
this product.
clean dry cloth.
mild detergent.
product in an environment where it is likely to
be subjected to chemicals, oils or solvents.
Cable aligned with
centre of seals
T
R
Status indicator