TFA01W TIMEGUARD, TFA01W Datasheet - Page 2

SOCKET, RCD, SINGLE, WHITE

TFA01W

Manufacturer Part Number
TFA01W
Description
SOCKET, RCD, SINGLE, WHITE
Manufacturer
TIMEGUARD
Datasheet

Specifications of TFA01W

Approval Category
BS7288 And BS1363
Colour
White
No. Of Gangs
1
No. Of Output Channels
1
Pack Quantity
1
Trip Time
40ms
Svhc
No SVHC (15-Dec-2010)
No. Of Outputs
1
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
General
The Timeguard range of RCDs provides protection against fire
hazard and rapid double pole disconnection from electric shock for
the appliance and cable connected to it. They comply fully with
BS7288 and BS1363. They are designed to mount on either a BS4662
recessed box or a BS5733 surface mount box (plastic versions only).
Note: RCD – Residual Current Device.
RCD Fused Connection Unit
Model: TFP10WL
Status indicator shows red for ‘ON’
Colour coded positive action
buttons for Testing and
Resetting the RCD
1
RED/ON
Fuse
RESET
TEST
Test (T) Befo re Use
Passive 30mA
BS1362 fuse
holder
The RCD fused connection unit is a latching (passive) version. If set,
this will retain closed contacts if the mains supply is interrupted –
essential for applications such as freezers.