TG550 AIM-TTI INSTRUMENTS, TG550 Datasheet - Page 4

FUNCTION GENERATOR FREQUENCY/PULSE, 5MHZ

TG550

Manufacturer Part Number
TG550
Description
FUNCTION GENERATOR FREQUENCY/PULSE, 5MHZ
Manufacturer
AIM-TTI INSTRUMENTS
Datasheet

Specifications of TG550

Signal Generator Type
Function
Bandwidth
5MHz
Modulation Type
AM, FM
Supply Voltage Range
220V To 240V
External Height
88mm
External Width
260mm
External Depth
235mm
Lead Free Status / RoHS Status
na
Frequency Range:
Vernier Range:
Operating Range:
Locking Accuracy:
LCD, 8 digits (11mm high) plus 14 annunciators
Frequency:
Amplitude:
DC Offset:
MAIN - 50 Ohm
Amplitide
Attenuator Ranges: 0dB, -20dB, -40dB, -60dB
DC Offset Range:
MAIN - 600 Ohm
AUX OUT
SWEEP OUT
Frequency Range:
Input Sensitivity:
Input Impedance:
Measurement Time: Selectable 0.5s or 5s
Resolution:
Accuracy:
Timebase Accuracy: ±10ppm initial error; ±5ppm/year ageing rate;
Technical Specifications
FREQUENCY
FREQUENCY LOCKING
DISPLAY
METER FUNCTIONS (generator mode)
OUTPUTS
EXTERNAL COUNTER
Designed and built in Europe by:
Glebe Road, Huntingdon. Cambs. PE29 7DX United Kingdom (UK)
Tel: 01480 412451 Fax: 01480 450409 Email: sales@tti-test.com
Thurlby Thandar Instruments Ltd.
Web Site: http://www.tti-test.com
0.005Hz to 5MHz in 7 overlapping decade
ranges with fine adjustment by verniers.
1000:1 on each range.
0.5Hz to 5MHz with vernier setting within
10% to 100% of range maximum.
Better than 0.01% of displayed value.
Auto-ranging reciprocal measurement giving
4 digit resolution for frequencies down to
1Hz; maximum resolution is 0.001Hz.
Accuracy ±1 digit 0.2Hz to 5MHz; accuracy
±1% of range full scale below 0.2Hz
Display shows peak-to-peak amplitude or rms
value. Display corrected for attenuator
setting. 3-digit resolution, accuracy typically
5% of range
3-digit resolution; accuracy typically ±2% of
setting ±1 digit. Display corrected for
attenuator setting
2mV to 20V peak-peak open circuit (1mV to
10V peak-peak into 50 ) in four
switch-selectable ranges with 20dB vernier
control within each range
±10V from 50 . DC offset plus signal peak
limited to ±10V (±5V into 50 ). DC offset
plus waveform attenuated proportionally by
the attenuator.
Alternative output socket offering the same
facilities as the 50 socket.
0 to 5V TTL/CMOS logic levels capable of
driving 2 standard TTL loads. Frequency,
symmetry and phase as main outputs
3V ramp from 600
5Hz to 20MHz, fully autoranging
50mV rms (sinewave)
1M /25pF
6 digits in 0.5s; 7 digits in 5s
±1 digit ± timebase accuracy
typically less then 0.5ppm/
point for closed-case recalibration
o
C. Adjustment
Specifications apply for the top decade of each frequency range and maximum
output into 50 termination.
SINE
Distortion:
Amplitude Flatness: ±0.2dB to 200kHz; ±2dB to 5MHz.
TRIANGLE
Linearity:
SQUARE WAVE
Rise/Fall Times:
Mark - Space Ratio: 1:1 ± 1% to 100kHz
DC
Range:
SYMMETRY
Symmetry Range:
INTERNAL
Sweep Range:
Sweep Rate:
Sweep Mode:
EXTERNAL
Input Impedance:
Input Sensitivity:
Max. Input Voltage: ±10V
Sweep Linearity:
Max. Voltage Rate: 0.1V/us
Depth:
Frequency:
External Sensitivity: Approx. 2V peak-to-peak for 50% modulation.
POWER REQUIREMENTS
AC Input:
Consumption:
ENVIRONMENTAL & MECHANICAL
Operating Range:
Storage Range:
Environmental:
Safety:
EMC:
Size:
Weight:
Thurlby Thandar Instruments Ltd. operates a policy of continuous development and
reserves the right to alter specifications without prior notice.
OPERATING MODES
SWEEP MODES
AMPLITUDE MODULATION
GENERAL
<0.5% on 500, 5k and 50k ranges; <1% on
5, 50 and 500k ranges; all harmonics >25dB
below fundamental on 5M range.
Better than 99% to 200kHz
<45ns
±10V unterminated
Variable typically 1:9 to 9:1 (on top decade of
each range), frequency divided by 10.
>1000:1 within each range.
Adjustable, typically 20ms to 20 secs.
Linear or logarithmic. Sweep start and stop
frequencies displayed by button press.
10k
0 to 3V for 1000:1 sweep
Better than 1%
Variable 0 to 100%
400Hz (internal). DC to 20kHz (external).
220 to 240 volts ±10% or 110 to 120 volts
±10% 50/60Hz, Installation Category II.
25VA max.
+5
-10
Indoor use at <2000m, Pollution degree 2
Complies with EN601010-1
Complies with EN61326
260(W) x 88(H) x 235(D)mm , excluding han-
dle and feet.
1.9kg approx.
o
C to +40
o
C to +65
o
C, 20% to 80% RH.
o
C
82100-0077 Iss. 2