DSO5032A AGILENT TECHNOLOGIES, DSO5032A Datasheet

OSCILLOSCOPE, 300MHZ, 2 CHANNEL, 2GSPS

DSO5032A

Manufacturer Part Number
DSO5032A
Description
OSCILLOSCOPE, 300MHZ, 2 CHANNEL, 2GSPS
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of DSO5032A

Scope Type
Digital
Scope Channels
2 Analog
Bandwidth
300MHz
Meter Display Type
TFT-LCD Color
Sampling Rate
2GSPS
Input Impedance
1Mohm
Rise Time
1.17ns
Input Voltage
400V P-p
Lead Free Status / RoHS Status
na
Agilent InfiniiVision 5000
Series Portable Oscilloscopes
Data Sheet
The Next Generation of Portable Oscilloscopes

DSO5032A Summary of contents

Page 1

The Next Generation of Portable Oscilloscopes Agilent InfiniiVision 5000 Series Portable Oscilloscopes Data Sheet ...

Page 2

The new standard for everyday scopes Traditional bench scopes are great for charac- terizing things that you know about. Agilent's MegaZoom III deep memory and fast update rates help you find the bugs you don’t know about. 2 • 100, ...

Page 3

... Model BW (MHz) Channels DSO5012A 100 2 DSO5014A 100 4 DSO5032A 300 2 DSO5034A 300 4 DSO5052A 500 2 DSO5054A 500 4 1 Maximum sample rate and memory are achieved when two channels are interleaved Industry-leading customer support As the world’ ...

Page 4

Why does deep memory matter? See more time Seeing more time is the most easily understood use of deep memory. The more samples you acquire, the more time you can see at a particular sample rate. Long capture times give ...

Page 5

Why does a fast update rate matter? If the human eye has trouble discerning above 30-50 frames per second, is there really a difference between 3,600 and 100,000 waveforms per second? If you know what you’re looking for, the answer ...

Page 6

Software options Figure 6A. On-screen serial decode of an SPI packet Figure 6B. Mask testing uncovers infrequent signal anomalies Figure 7. Real-time totalize functions provide CAN bus efficiency and quality measurement statistics 2 Figure Configuration PNG 6 ...

Page 7

Software options (continued) Figure 9. Trigger on and decode RS-232/UART transmission Figure 10. Use segmented memory to optimize available memory Figure 11. Time-correlated display of the FlexRay physical layer signal with protocol decoding. Figure 12. Time-correlated display of the MIL-STD ...

Page 8

Other nice features High resolution mode Offers bits of vertical resolution in real-time, single-shot mode. This is accomplished by serially filtering sequential data points and mapping the filtered results to the display when operating at base time ...

Page 9

... This feature is also compatible with Agilent’s Segmented Memory option (SGM) Oscilloscope tools E2690B Oscilloscope tools package, licensed by Agilent Technologies from Amherst Systems Associates (ASA), makes it easy to perform in- depth analysis of captured signals. More information can be found in the Oscilloscope Tools data sheet (Agilent publication number 5989-3525EN) ...

Page 10

Probing To get the most out of your scope, you need the right probes and accessories for your application. That’s why Agilent Technologies offers a complete family of innovative passive and active probes for the 5000 Series scopes to help ...

Page 11

Probing (continued) Selection guide (continued) Current probes Description 1147A 50-MHz 115 A current probe, AC/DC 1146A 100-kHz current probe, AC/DC N2780A 2-MHz/500 A current probe, AC/DC N2781A 10-MHz/150 A current probe, AC/DC N2782A 50-MHz/30 A current probe, AC/DC N2783A 100-MHz/30 ...

Page 12

Connectivity Our customers tell us that oscilloscope connectivity is an increasingly important feature of their test instruments. That’s why the 5000 Series scopes come with the most comprehensive hardware and software connectivity tools in their class. Hardware connectivity Standard ports ...

Page 13

Performance characteristics Acquisition Sample rate DSO501xA/503xA: 2 GSa/a each channel DSO505xA: 4 GSa/s half channel Equivalent-time sample rate 400 GSa/s (when real-time mode is turned off) Memory depth Standard 8 Mpts half channel1 , 4 Mpts each channel Vertical resolution ...

Page 14

Performance characteristics Vertical system (continued) 1 Range 2 mV/div to 5 V/div (1 MΩ Ω) Maximum input Maximum input voltage for analog inputs: CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk CAT II 100 Vrms, 400 ...

Page 15

Performance characteristics Horizontal Range DSO501xA: 5 nsec/div to 50 sec/div DSO503xA: 2 nsec/div to 50 sec/div DSO505xA: 1 nsec/div to 50 sec/div Resolution 2.5 psec Time scale accuracy* Specification: 25 ppm from 0 ° °C Characteristic: 25 ppm ...

Page 16

Performance characteristics Trigger system (continued) Selections Edge, pulse width, pattern, TV, duration Edge Trigger on a rising, falling, or alternating edge of any source Pulse width Trigger when a positive- or negative-going pulse is less than, greater than, or within ...

Page 17

Performance characteristics Channel triggering Range (internal) ±6 div from center screen 1 Sensitivity < 10 mV/div: greater of 1 div or 5mV; ≥ 10 mV/div: 0.6 div Coupling AC (~10 Hz), DC, noise reject, HF reject and LF reject (~50 ...

Page 18

Performance characteristics Measurement features Automatic measurements Measurements are continuously updated. Cursors track last selected measurement. Voltage Peak-to-peak, maximum, minimum, average, amplitude, top, base, overshoot, preshoot, RMS, standard deviation, Ratio (dB) Time Frequency, period, + width, – width and duty cycle ...

Page 19

Performance characteristics General characteristics Physical size 35.4 cm wide x 18.8 cm high x 17.4 cm deep (without handle) 38.5 cm wide x 18.8 cm high x 17.4 cm deep (with handle) Weight Net: 4 lbs) Shipping: approximately ...

Page 20

... Available models Product number Description DSO5012A 100 MHz, 2-channel portable oscilloscope DSO5014A 100 MHz, 4-channel portable oscilloscope DSO5032A 300 MHz, 2-channel portable oscilloscope DSO5034A 300 MHz, 4-channel portable oscilloscope DSO5052A 500 MHz, 2-channel portable oscilloscope DSO5054A 500 MHz, 4-channel portable oscilloscope ...

Page 21

Ordering information (continued) Options Product number Description SEC Secure environment mode – Provides compliance with National Industrial Security Program Operating Manual (NISPOM) Chapter 8 requirements A6J ANSI Z540-compliant calibration 080 8 Mpts memory upgrade (from base 1 Mpts) Serial data ...

Page 22

... Multiple form factors from 20 MHz to >90 GHz 22 Agilent Technologies Oscilloscopes | Industry leading specs | Powerful applications ...

Page 23

... For more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt www.agilent.com www.agilent.com/find/5000a For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada ...