Y8846D Tektronix, Y8846D Datasheet
Y8846D
Specifications of Y8846D
Y8846D Summary of contents
Page 1
... Digital Multimeters Tektronix DMM4020 Data Sheet DMM4020 Features & Benefits Key Performance Specifications 5.5 Digit Resolution Basic VDC Accuracy 0.015% (1 yr.) 200 mV to 1000 V Voltage Range, with μV Resolution 200 μ Current Range, with Resolution 200 Ω to 100 MΩ Ohm Range, with mΩ Resolution ...
Page 2
... As the circuits in embedded system designs become more sophisticated, you must measure a multitude of different parameters to validate your design. The Tektronix DMM4020 5.5 digit bench multimeter offers a broad range of functions in one easy-to-use instrument. Typical multimeter measurements – volts, ohms, and amps – are made with a basic VDC accuracy ...
Page 3
... PC. Only Tektronix offers a connected test bench of intelligent instruments to simplify and speed debug of your complex design. Performance You Can Count On In addition to industry-leading service and support, every DMM4020 multimeter comes backed with a three-year standard warranty ...
Page 4
... Complies with MIL-PRF-28800F Class 3 Safety Complies with IEC 61010-1:2001, ANSI/ISA 61010-1 (S82.02.01):2004, UL 61010-1:2004, CAN/CSA C22.2 No. 61010.1:2004, CAT I 1000V / CAT II 600 V EMC Designed to comply with IEC 61326-1:1997+A1:1998+A2:2000 4 www.tektronix.com Triggering Characteristic Trigger Delay External Trigger Delay External Trigger Jitter Trigger Input Trigger Output Math Functions Min/max, relative, hold, compare, and dB functions in ...
Page 5
... Digital Multimeters — Tektronix DMM4020 Input Impedance Fast 10 μV >10 GΩ* 2 100 μV >10 GΩ* 2 1000 μV 10 MΩ ± MΩ ...
Page 6
... Hz – 20 kHz 20 kHz – 50 kHz 50 kHz – 100 kHz 750 – – 20 kHz 20 kHz – 50 kHz 50 kHz – 100 kHz * Uncertainty given as ±(% of reading + % of range www.tektronix.com Volts-Hertz product 7 Resolution Slow Medium 1 μV 10 μV 10 μV 100 μV 100 μV 1000 μV ...
Page 7
... Digital Multimeters — Tektronix DMM4020 Current Source Fast 0.01 Ω 0.8 mA 0.1 Ω 0 Ω 0. Ω 0.008 mA 100 Ω ...
Page 8
... A 1.99999 10.0000 A Accuracy Range 200 μ 200 Uncertainty given as ±(% of reading + % of range www.tektronix.com Resolution Slow Medium 0.001 μA 0.01 μA 0.01 μA 0.1 μA 0.1 μA 1 μA 1 μA 10 μA 10 μA 100 μA 100 μ Uncertainty days 1 year 23 ° ...
Page 9
... Accuracy Range Frequency kHz 200 kHz kHz kHz * Uncertainty given as ±(% of reading + % of range). 3 Digital Multimeters — Tektronix DMM4020 Resolution Slow Medium 0.1 μA 1 μA 1 μA 10 μA 10 μA 100 μA 100 μ Uncertainty days 23 °C ±5 °C 23 °C ±5 ° 0.05 1.25 + 0.06 ...
Page 10
... Test Current Response Time 100 S/s with audible tone Rate Fast Maximum Reading 199.99 Ω Resolution 0.01 Ω 10 www.tektronix.com Uncertainty 90 days 1 year 23 °C ±5 °C 23 °C ±5 °C 0.01 + 0.002 0.01 + 0.003 0.01 + 0.002 0.01 + 0.003 0.01 + 0.002 0.01 + 0.003 ...
Page 11
... Wire Ohm SMD Test Tweezers AC4000 Soft Transit Case HCTEK4321 Hard Carrying Case Y8846S Single Rackmount Kit Y8846D Dual Rackmount Kit 013-0369-xx Calibration Fixture 4-terminal short SIGEXPTE NI LabVIEW SignalExpress Tektronix Edition Software – Full Version Product(s) are manufactured in ISO registered facilities. ...
Page 12
... Please visit www.tektronix.com Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. ...